Results 181 to 190 of about 641,323 (222)
Some of the next articles are maybe not open access.

Thermally stimulated optical scintillations in preheated plastic scintillators

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992
Abstract PVT-based plastic scintillators, irrespective of their radiation history, are found to exhibit thermally stimulated optical scintillations in the temperature interval 40–80°C following a preheat to 200°C or above and cooling to RT. Maximum scintillation activity occurs near 65°C, which is the glass transition temperature T g of the ...
M.S. Jahan   +4 more
openaire   +1 more source

Characteristics of Plastic Scintillators

The Journal of Chemical Physics, 1957
Information on the light output of a group of organic solutes in polyvinyltoluene has been obtained. The primary solutes studied are p-terphenyl and 2-phenyl-5-(4-biphenylyl)-1,3,4 oxadiazole (PBD), the latter being the most efficient. Of the secondary solutes studied, 4,4′-diphenylstilbene and 2,5-dibiphenylyl oxazole (BBO) are the most efficient. The
openaire   +1 more source

Plastic Scintillators. III. The Synthesis of Some Anthracene Derivatives as Wavelength Shifters in Plastic Scintillators

Bulletin of the Chemical Society of Japan, 1966
Abstract Fifteen anthracene derivatives have been synthesized, and their absorption and fluorescence spectra have been measured. The spectra will be discussed in this paper. According to the spectra, some of anthracene derivatives synthesized here are better wavelength shifters than the compounds previously described in the literature.
Tadao Nakaya   +2 more
openaire   +1 more source

Mechanoluminescence of plastic scintillation counters

Journal of Luminescence, 2000
Luminescence has been observed from the mechanical deformation of plastic scintillation materials. The light was recorded by means of a photomultiplier, and observed on a monitor by means of an intensified CCD camera. There is evidence for piezoluminescence as well as triboluminescence.
G.T. Reynolds, R.H. Austin
openaire   +1 more source

Sub-Nanosecond Plastic Scintillators

IEEE Transactions on Nuclear Science, 1977
Quenched plastic scintillators have been developed that yield much faster short decay components and greatly reduced long decay components compared to conventional plastic scintillators. The plastics are produced through the addition of selected quench agents to NE111 plastic scintillator that result in reduced total light output.
P. B. Lyons   +7 more
openaire   +1 more source

Preparation of Large Plastic Scintillators

Review of Scientific Instruments, 1957
A process is described for the manufacture of disks of plastic scintillators weighing over 100 kg and composed of polystyrene (∼99%), p-terphenyl (∼1%), and POPOP (∼0.03%). The design and performance of two large plastic scintillation detectors for cosmic rays are discussed.
G. W. Clark, F. Scherb, W. B. Smith
openaire   +1 more source

Optical measurement of fogged scintillator plastics and development of non-fogging plastic scintillator formulations

Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XXII, 2020
In 2010, light scattering defects were observed in several fielded panels of poly(vinyltoluene) plastic scintillators that had experienced losses in radiation sensitivity. Pacific Northwest National Laboratory first deduced that the defects were caused by trapped water.
openaire   +1 more source

Mass discrimination with plastic scintillators

Nuclear Instruments and Methods, 1962
Abstract Mass discrimination of protons, deuterons and tritons, is shown to be possible from 8 to 50 MeV, by obtaining a suitable product of the outputs of d E /d x and E plastic scintillation detectors in a counter telescope. The non-linear energy response of the scintillator NE102 is taken into account in the calculation of the function which ...
R.J. Griffiths   +3 more
openaire   +1 more source

Radiation damage in plastic scintillators

Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference, 2002
Summary form only given, as follows. Radiation damage in 408 and 412 plastic scintillators and two new plastic fibers has been studied by measuring, in the BNL (Brookhaven National Laboratory) radiation facility, the scintillation output during irradiation with /sup 60/Co gamma rays at room temperature. In all studies the luminescence intensity changes,
P.W. Levy, J.A. Kierstead
openaire   +1 more source

Luminescence of plastic scintillators

Uspekhi Fizicheskih Nauk, 1959
I M Rozman, S F Kilin
openaire   +1 more source

Home - About - Disclaimer - Privacy