Results 31 to 40 of about 15,556 (297)
This paper describes a new combined impedance plethysmographic (IPG) and electrical bioimpedance spectroscopic (BIS) instrument and software that allows noninvasive real-time measurement of segmental blood flow and changes in intracellular, interstitial,
Montgomery Leslie D.+5 more
doaj +1 more source
CONTACTLESS MEASUREMENT OF KEY PARAMETERS OF LIMB VESSELS ON AN OCCLUSAL PLETHYSMOGRAPHY METHOD
The purpose of this publication – to familiarize the readers with the newest achievements in the field of vision machine technologies with regard to the occlusal plethysmography.
V. I. Kuznetsov+2 more
doaj +1 more source
Fluid responsiveness in the pediatric population [PDF]
It is challenging to predict fluid responsiveness, that is, whether the cardiac index or stroke volume index would be increased by fluid administration, in the pediatric population. Previous studies on fluid responsiveness have assessed several variables
Ji-Hyun Lee+4 more
doaj +1 more source
The effect of combined glutamate receptor blockade in the NTS on the hypoxic ventilatory response in awake rats differs from the effect of individual glutamate receptor blockade. [PDF]
Ventilatory acclimatization to hypoxia (VAH) increases the hypoxic ventilatory response (HVR) and causes persistent hyperventilation when normoxia is restored, which is consistent with the occurrence of synaptic plasticity in acclimatized animals ...
Carr, John A+3 more
core +2 more sources
OBJECTIVES Pulsus paradoxus is one of the few objective bedside measures of acute asthma exacerbation severity but is difficult to measure in tachypneic and tachycardic patients and in noisy clinical environments.
Donald H. Arnold, Li Wang, T. Hartert
semanticscholar +1 more source
Discrepancy in finger pulse oximetry reading related to positioning: a case report
Pulse oximetry is one of the five cardinal vital signs used to monitor patients in the clinical setting, and has contributed significantly to patient safety.
Yi Lin Lee, Meng Huat Goh, Yee Yian Ong
doaj +1 more source
An assessment of pulse transit time for detecting heavy blood loss during surgical operation [PDF]
Copyright @ Wang et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non ...
Anderson ID+20 more
core +1 more source
In animals, emotional memory is classically assessed through pavlovian fear conditioning in which a neutral novel stimulus (conditioned stimulus) is paired with an aversive unconditioned stimulus.
Chloe eHegoburu+11 more
doaj +1 more source
Respiration rate and volume measurements using wearable strain sensors. [PDF]
Current methods for continuous respiration monitoring such as respiratory inductive or optoelectronic plethysmography are limited to clinical or research settings; most wearable systems reported only measures respiration rate.
Bar-Yoseph, Ronen+9 more
core +2 more sources
Satisfactory methods, utilizing measurements of transthoracic or transpulmonary pressure and airflow, are now available for determining "nonelastic" pulmonary resistance.
A. Dubois, S. Botelho, J. H. Comroe
semanticscholar +1 more source