Results 51 to 60 of about 15,556 (297)

Contactless cardiac gating at 0.55T using high‐amplitude pilot tone with interference cancellation (HAPTIC)

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose To enable contactless cardiac gating at 0.55T using pilot tone (PT). Current PT methods are unable to extract weak motions, including cardiac motion, at lower B0 field strengths (<1.5T). Methods We utilize high‐amplitude pilot tone with interference cancellation, termed HAPTIC.
Bilal Tasdelen   +4 more
wiley   +1 more source

Towards an Automatic Recognition of Artifacts and Features in Plethysmographic Traces

open access: yesApplied Sciences
A plethysmograph is a device that quantitatively assesses volumetric variations in an organ or the entire body, typically resulting from fluctuations in blood flow.
Alessandro Breccia   +7 more
doaj   +1 more source

New electrical plethysmograph monitors cardiac output [PDF]

open access: yes, 1968
Four-electrode impedance plethysmograph measures ventricular stroke volume of cardiac output of humans.
Kubicek, W. B.   +2 more
core   +1 more source

Evaluation of a new air displacement plethysmograph for measuring human body composition.

open access: yesMedicine & Science in Sports & Exercise, 1995
A new air displacement plethysmograph, the BOD POD (BP), was evaluated in comparison to hydrostatic weighing (HW). Sixty-eight adult subjects (26 F, 42 M) varying widely in age (range 20-56 yr), ethnicity, and fatness participated in this study. Same-day
M. McCrory   +3 more
semanticscholar   +1 more source

Respiratory pattern, thoracoabdominal motion and ventilation in chronic airway obstruction

open access: yesMonaldi Archives for Chest Disease, 2016
Background. Patients with chronic obstructive pulmonary disease (COPD) present abnormal respiratory mechanics, but its relation to ventilation variables at rest is not fully understood. Methods.
M. Fernandes   +4 more
doaj   +1 more source

Readout electrode assembly for measuring biological impedance [PDF]

open access: yes, 1976
The invention comprises of a pair of readout ring electrodes which are used in conjunction with apparatus for measuring the electrical impedance between different points in the body of a living animal to determine the amount of blood flow therebetween ...
Montgomery, L. D., Moody, D. L., Jr.
core   +1 more source

Unique features of seizure‐induced cardiorespiratory failure in SSKcnj16−/− rats: Implications for sudden unexpected death in epilepsy

open access: yesEpilepsia, EarlyView.
Abstract Objective Patients with uncontrolled epilepsy are at high risk for sudden unexpected death in epilepsy (SUDEP), which likely results from a pathological, seizure‐induced disruption of vital physiological systems. The objective of this study was to characterize seizure‐induced physiological dysfunction leading to death in SSKcnj16−/− rats and ...
Melissa Eilbes   +5 more
wiley   +1 more source

Supervised Release, Sex-Offender Treatment Programs, and Substantive Due Process [PDF]

open access: yes, 2016
This Note argues that mandated PPG testing should be eliminated as a condition of federal supervised release. The test infringes on a constitutionally protected liberty interest against unwanted bodily intrusions and, as only the Second Circuit has held,
Bernstein, Max B.
core   +1 more source

Longitudinal Changes in Aerodigestive Responses to Varying Nipple Properties in Infant Pigs

open access: yesJournal of Experimental Zoology Part A: Ecological and Integrative Physiology, Volume 343, Issue 5, Page 608-616, June 2025.
ABSTRACT Coordination of respiration and swallowing is critical for survival in infant mammals and changes throughout infant maturation. Infants show sensorimotor feeding responses to changes in physical properties of nipples. Commercial nipples are promoted as improving aerodigestive coordination. However, it is unknown how nipple properties influence
François D. H. Gould   +6 more
wiley   +1 more source

Speckle Plethysmograph-Based Blood Pressure Assessment

open access: yesTechnologies
Continuous non-invasive blood pressure (CNBP) monitoring is of the utmost importance in detecting and managing hypertension, a leading cause of death in the United States.
Floranne T. Ellington   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy