Barometric whole-body plethysmography investigating breed-specific variations in dogs [PDF]
IntroductionBarometric whole-body plethysmography (BWBP) is a non-invasive method for pulmonary function testing in dogs. A significant advantage over other techniques is the possibility to perform measurements in awake and unrestrained animals ...
Charlotte Münch +4 more
doaj +2 more sources
Measuring Breathing Patterns in Mice Using Whole-body Plethysmography
Respiratory dysfunction is among the main cause of severe and fatal pathologies worldwide. The use of effective experimental models and methodologies for the study of the pulmonary pathophysiology is necessary to prevent, control and cure these diseases.
Patricia Prada-Dacasa +4 more
doaj +3 more sources
Characterisation of Brachycephalic Obstructive Airway Syndrome in French Bulldogs Using Whole-Body Barometric Plethysmography. [PDF]
Brachycephalic obstructive airway syndrome (BOAS) is an important health and welfare problem in several popular dog breeds. Whole-body barometric plethysmography (WBBP) is a non-invasive method that allows safe and repeated quantitative measurements of ...
Nai-Chieh Liu +3 more
doaj +6 more sources
Automated Classification of Whole Body Plethysmography Waveforms to Quantify Breathing Patterns [PDF]
Whole body plethysmography (WBP) monitors respiratory rate and depth but conventional analysis fails to capture the diversity of waveforms. Our first purpose was to develop a waveform cluster analysis method for quantifying dynamic changes in respiratory
Michael D. Sunshine +6 more
doaj +3 more sources
Whole‐Body Barometric Plethysmography Characterizes Upper Airway Obstruction in 3 Brachycephalic Breeds of Dogs [PDF]
Background A novel test using whole‐body barometric plethysmography (WBBP) was developed recently to diagnose brachycephalic obstructive airway syndrome (BOAS) in unsedated French bulldogs.
N‐C. Liu +4 more
doaj +3 more sources
A importância do estudo da difusão alvéolo-capilar, como complemento da pletismografia, na avaliação funcional de fumadores [PDF]
Resumo: Foram estudados 194 casos de fumadores e exfumadores (⥠1 UMA), de ambos os sexos e idades compreendidas entre os 20 e os 82 anos, tendo sido excluÃdos doentes detentores de patologias ou antecedentes profissionais de risco.
António Paes Cardoso +2 more
doaj +3 more sources
Can the single-breath alveolar volume be adjusted to estimate true total lung capacity? [PDF]
Background Total lung capacity (TLC) measured with single-breath gas diffusion (TLCsb) is systematically lower than TLC measured with whole-body plethysmography (TLCwbp) especially in patients with obstructive defects.
Simon Kristoffer Høgh Rasmusen +1 more
doaj +2 more sources
Comparison of lung volumes measured with computed tomography and whole-body plethysmography – a systematic review [PDF]
Introduction Whole-body plethysmography is the preferred method for measuring the static lung volumes: total lung capacity (TLC), functional residual capacity (FRC) and residual volume (RV), as it also incorporates trapped gas – a common finding in ...
Høgni Janus Bjarnason Olsen +1 more
doaj +2 more sources
Whole-body plethysmography revisited [PDF]
AbstractWhole-body plethysmography (WBP) is an established method to determine physiological parameters and pathophysiological alteration of breathing in animals and animal models of a variety of diseases, reaching from pulmonary diseases to complex neurological syndromes. Although frequently used, there is ongoing debate about what exactly is measured
Swen Hülsmann +5 more
openaire +1 more source
Evaluation of a mechanical lung model to test small animal whole body plethysmography
Whole-body plethysmography (WBP) is an established method to determine physiological parameters and pathophysiological alteration of breathing in animals and animal models of a variety of diseases.
Swen Hülsmann +5 more