Results 191 to 200 of about 35,571 (251)

Small Airways Disease Adversely Impacts the Response to Biologic Therapies in Severe Asthma. [PDF]

open access: yesPulm Ther
Allegrini C   +11 more
europepmc   +1 more source

The silent zone of paediatric asthma: integrating small airway dysfunction assessment into clinical practice. [PDF]

open access: yesEClinicalMedicine
Indolfi C   +5 more
europepmc   +1 more source

TECHNIQUES OF PLETHYSMOGRAPHY

Psychophysiology, 1965
ABSTRACTFour plethysmographic techniques‐rheoplethysmography, electrical impedance plethysmography, girth plethysmography, and photoplethysmography–are described and their theoretic bases discussed. Advantages and limitations are noted, and particular emphasis is given to the optical methods and the use of glass fiber light guides in the construction ...
C C, BROWN, D B, GIDDON, E D, DEAN
openaire   +4 more sources

Impedance plethysmography

Equine Veterinary Journal, 1990
Summary The technique of impedance plethysmography is described and its application to observation of lung volume changes in the horse at exercise is discussed. The results from horse at rest show that there is a close relationship between rate of lung volume change (flow rate) and the associated impedance changes during both ...
D P, Attenburrow   +2 more
openaire   +2 more sources

Features of Pulse Plethysmography and a Comparison with Impedance Plethysmography

Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1992
The features of current pulse plethysmography are given. The skin capacitance and resistance are depending upon pulse duration but not the internal resistance. The internal resistance changes depend of arteries volume changes. A comparison between pulsed plethysmography and sine-wave plethysmography is discussed.
null Santic, null Saban
openaire   +2 more sources

Comparison of electrical field plethysmography with electrical impedance plethysmography

Annals of Biomedical Engineering, 1982
As a means for assessing cardiac function, electrical field plethysmography (EFP) has been shown to have some features quite different from electrical impedance plethysmography (EIP). Here the two techniques are compared by using the two systems simultaneously on a subject and also with independent use in different electrode configurations. The results
S K, Guha, S, Anand
openaire   +2 more sources

Venous occlusive RN plethysmography: Comparison with electrical admittance plethysmography

Journal of Biomedical Engineering, 1984
A venous occlusion plethysmography using radionuclide (RN) was introduced for the measurement of the limb blood flow. This technique, called RN plethysmography, can be carried out in a subject who has been previously administered RN intravenously for the routine angiographic examination.
M, Fukuoka   +5 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy