Results 91 to 100 of about 1,762,518 (330)
Abstract Purpose To generate high‐quality stereotactic radiosurgery (SRS) plans for single cranial lesions using 4Pi planning technique and compare these to our clinical “status quo” plans. Methods Eighteen vestibular schwannoma (VS) patients previously planned with Varian Eclipse RapidArc and treated on a Varian TrueBeam using 6FFF MV photon beams ...
Ganesh Narayanasamy+4 more
wiley +1 more source
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa+4 more
wiley +1 more source
Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda+9 more
wiley +1 more source
A Density-Aware Point Cloud Geometry Compression Leveraging Cluster- Centric Processing
Recent years have encountered a noticeable expansion of point cloud-based 3D applications that compels the necessity of high-efficiency point cloud compression.
Fariha Afsana+3 more
doaj +1 more source
SOME VITAL POINTS IN THE TEACHING OF GEOMETRY [PDF]
n ...
openaire +3 more sources
Automated rapidplan model validation using Eclipse scripting API
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma+2 more
wiley +1 more source
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen+3 more
wiley +1 more source
True coincidence summing correction factor for point source geometry with PHITS
In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program.
Esra Uyar
doaj
Abstract Purpose Stereotactic radiotherapy (SRT) is a highly effective treatment with precision for small, localized lesions. Proton therapy, characterized by the Bragg peak, offers superior dose conformity compared to photon‐based approaches. However, challenges remain in minimizing lateral penumbra and optimizing dose delivery, particularly for small
Chen‐Yu Chou+3 more
wiley +1 more source
Localization accuracy of 6‐second CBCT for lung IGRT with various breathing patterns
Abstract Purpose The 6‐second cone beam computed tomography (CBCT) acquisition of the Ethos HyperSight (Varian Medical Systems, Inc. Palo Alto, CA, USA) on‐board imaging system offers benefits, but could be too fast to accurately capture an average target position in a free‐breathing lung cancer patient. This study aimed to ascertain whether a 6‐second
Jihye Koo+5 more
wiley +1 more source