Results 181 to 190 of about 4,911 (228)
Some of the next articles are maybe not open access.
American Journal of Obstetrics and Gynecology, 2006
The goal of our study was to compare the impact of 3 suture materials on perineal pain and on resumption of sexual intercourse.This randomized, controlled trial compared 3 types of suture materials (chromic catgut, polyglactin 910, fast-absorbing polyglactin 910) for second-degree perineal laceration or uncomplicated episiotomy.
Nathalie, Leroux, Emmanuel, Bujold
openaire +2 more sources
The goal of our study was to compare the impact of 3 suture materials on perineal pain and on resumption of sexual intercourse.This randomized, controlled trial compared 3 types of suture materials (chromic catgut, polyglactin 910, fast-absorbing polyglactin 910) for second-degree perineal laceration or uncomplicated episiotomy.
Nathalie, Leroux, Emmanuel, Bujold
openaire +2 more sources
Reconstruction of Orbital Wall Fenestrations with Polyglactin 910 Film
Plastic and Reconstructive Surgery, 1987Medial orbital wall fenestrations were created bilaterally in 16 adult cats. The fenestrations were reconstructed with polyglactin 910 film, Dacron-reinforced silicone sheeting, or no implant. Polyglactin 910 was found to be well tolerated in this traumatized area of paranasal sinus bone and soft tissue and was totally absorbed in 4 months.
W D, Morain +4 more
openaire +2 more sources
Comparison of Poliglecaprone-25 and Polyglactin-910 in Cutaneous Surgery
Dermatologic Surgery, 2013Few clinical studies have compared deep absorbable sutures. Poliglecaprone-25 and polyglactin-910 are two of the most commonly used absorbable sutures in cutaneous surgery.To compare the rate of suture extrusion, degree of lumpiness, and appearance of scars from wounds closed with poliglecaprone-25 and polyglactin-910.Poliglecaprone-25 or polyglactin ...
Thomas, Regan, Naomi, Lawrence
openaire +2 more sources
Repair of Spinal Dural Defects with Vicryl (Polyglactin 910) Mesh
Journal of Spinal Disorders, 1989This study examined and compared the effectiveness of woven vicryl (polyglactin 910) mesh and lyophilized cadaver dura (Lyodura) for the repair of spinal dural defects. A woven vicryl mesh was used to repair spinal dural defects in 16 mongrel dogs. As an internal control, all animals had a separate dural incision that was closed with 9-0 vicryl suture.
J T, Keller +5 more
openaire +2 more sources
Revue de Stomatologie, de Chirurgie Maxillo-faciale et de Chirurgie Orale, 2013
Summary Introduction Two different types of suture are used in our unit after wisdom tooth extraction, Polyglactin 910 [PGS] (Vicryl ® , Ethicon) and rapid absorption irradiated Polyglactin 910 [PGI]. No objective comparative study was available so we decided to conduct a preliminary prospective study to check if there was any difference between ...
B. Bertrand +6 more
openaire +1 more source
Summary Introduction Two different types of suture are used in our unit after wisdom tooth extraction, Polyglactin 910 [PGS] (Vicryl ® , Ethicon) and rapid absorption irradiated Polyglactin 910 [PGI]. No objective comparative study was available so we decided to conduct a preliminary prospective study to check if there was any difference between ...
B. Bertrand +6 more
openaire +1 more source
Irradiated polyglactin 910 for mucosal defects.
Cutis, 2008The prolonged presence of superficial mucosal sutures or perineal sutures may cause irritation or discomfort and increase the risk of bacterial infections. Although absorbable sutures are commonly used in mucosal areas, many sutures have a prolonged half-life and might still require removal when used superficially.
Sina, Aboutalebi, Michael J, Wells
openaire +1 more source
Rescue Polyglactin 910 for Zygomatic Communited Fractures
Surgical Innovation, 2021Kalyani Bhate +2 more
openaire +2 more sources
Orbit, 2002
To assess the safety and efficacy of 7/0 Vicryl and 7/0 Vicryl rapide sutures for skin closure, and without suture removal, in ophthalmic plastic surgery.A prospective, comparative study of 40 consecutive procedures in 32 patients. Tissue reactions to the sutures, completeness of wound healing, and number of sutures remaining were observed at first ...
A W R, Talbot +3 more
openaire +2 more sources
To assess the safety and efficacy of 7/0 Vicryl and 7/0 Vicryl rapide sutures for skin closure, and without suture removal, in ophthalmic plastic surgery.A prospective, comparative study of 40 consecutive procedures in 32 patients. Tissue reactions to the sutures, completeness of wound healing, and number of sutures remaining were observed at first ...
A W R, Talbot +3 more
openaire +2 more sources
[Pelvic peritonization with a polyglactin 910 mesh].
Presse medicale (Paris, France : 1983), 1984The authors, who have a long experience of polyglactin 910 mesh advocate its use for pelvic peritonization in two different situations and with two different techniques. The "lower controlled peritonization" technique aims at obtaining rapid and satisfactory healing of the peritoneum in wide resections or resections in high risk patients.
E, Lehn, J C, Levasseur
openaire +1 more source
Revue de stomatologie, de chirurgie maxillo-faciale et de chirurgie orale, 2014
Two different types of suture are used in our unit after wisdom tooth extraction, Polyglactin 910 [PGS] (Vicryl®, Ethicon) and rapid absorption irradiated Polyglactin 910 [PGI]. No objective comparative study was available so we decided to conduct a preliminary prospective study to check if there was any difference between these two types of suture ...
B, Bertrand +6 more
openaire +1 more source
Two different types of suture are used in our unit after wisdom tooth extraction, Polyglactin 910 [PGS] (Vicryl®, Ethicon) and rapid absorption irradiated Polyglactin 910 [PGI]. No objective comparative study was available so we decided to conduct a preliminary prospective study to check if there was any difference between these two types of suture ...
B, Bertrand +6 more
openaire +1 more source

