Results 21 to 30 of about 799,943 (286)

Worldwide enucleation techniques and materials for treatment of retinoblastoma: an international survey.

open access: yesPLoS ONE, 2015
PurposeTo investigate the current practice of enucleation with or without orbital implant for retinoblastoma in countries across the world.MethodsA digital survey identifying operation techniques and material used for orbital implants after enucleation ...
Daphne L Mourits   +4 more
doaj   +1 more source

Probabilistic finite element analysis of the uncemented hip replacement-effect of femur characteristics and implant design geometry [PDF]

open access: yes, 2010
In the present study, a probabilistic finite element tool was assessed using an uncemented total hip replacement model. Fully bonded and frictional interfaces were investigated for combinations of three proximal femurs and two implant designs, the ...
Dopico González, Carolina   +2 more
core   +1 more source

Influence of cementless hip stems on femoral cortical strain pattern depending on their extent of porous coating [PDF]

open access: yes, 2012
The extent of porous coating of cementless total hip stems is held responsible for radiological periprosthetic changes, the rate of thigh pain, and even its long-term success.
Steinhauser, Erwin   +4 more
core   +1 more source

Risk factors for orbital implant exposure after evisceration: A case control study of 93 patients

open access: yesIndian Journal of Ophthalmology, 2019
Purpose: The study aims to analyze risk factors for exposure of orbital implants after evisceration by comparison of patients with and without exposure of implants.
Roshmi Gupta   +3 more
doaj   +1 more source

The posterior auricular muscle complex graft as a porous orbital implant wrap: long-term follow-up over a 31-year period

open access: yes, 2023
Purpose: Orbital implant exposures, infections, and extrusions can occur many years following enucleation or evisceration. This study analyzes complication rates following porous orbital implant wrapped with a posterior auricular muscle complex graft ...
Callahan, Michael A.   +9 more
core   +1 more source

Structure and thermomechanics of selective laser melted nickel-titanium [PDF]

open access: yes, 2015
NiTi has been established for applications in load-bearing implants due to its mechanical properties, which mimic the characteristics of bone better than any other known biocompatible metal or metallic alloy.
Bormann, Anna Therese
core   +1 more source

Outcome of porous polyethylene implants in anophthalmic sockets with implant migration

open access: yesKerala Journal of Ophthalmology
Purpose: To evaluate the surgical outcome of porous polyethylene orbital implants in anophthalmic sockets with implant migration. Methods: A prospective interventional case series: Patients of anophthalmic sockets with implant migration were recruited ...
Anju Bhari   +4 more
doaj   +1 more source

Tissue engineering for total meniscal substitution : Animal study in sheep model [PDF]

open access: yes, 2008
Objective: The aim of the study was to investigate the use of a novel hyaluronic acid/polycaprolactone material for meniscal tissue engineering and to evaluate the tissue regeneration after the augmentation of the implant with expanded autologous ...
Salter, Donald M.   +32 more
core   +1 more source

Functionalizing Micro‐to‐Mesoscopic Electrode Architectures for Regulating Electron Transfer Behaviors in Electrocatalysis

open access: yesAdvanced Functional Materials, EarlyView.
A systematic review is conducted to assess the influence of electrode architecture across micro‐ to mesoscopic length scales on electron‐transfer pathways in electrocatalysis. We discuss the structure‐activity relationships in electrocatalytic applications, including resource recovery and environmental remediation, and provide cost‐effective, efficient
Manshu Zhao   +6 more
wiley   +1 more source

Comparison between local-made and imported porous polyethylene orbital implant: a randomized controlled equivalence trial and multicenter study [PDF]

open access: yesInternational Journal of Ophthalmology
AIM: To compare the exposure rate, infection rate, percentage of enhancement, and success rate between Medpor and the three-dimensional printed polyethylene (3DP-PE) orbital implant in a preliminary report.
Sunisa Sintuwong   +12 more
doaj   +1 more source

Home - About - Disclaimer - Privacy