Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry

open access: yesJournal of Medical Signals and Sensors, 2017
Dosimetric verification of radiation treatment has recently been extended by the introduction of electronic portal imaging devices (EPIDs). Detailed dose response specifications of EPID should be addressed prior to any dosimetric application. The present
Vahideh Nazari   +6 more
doaj   +2 more sources

Quantitative evaluation of the effect of anatomical changes on the results of in vivo dosimetry during radiation therapy in the thoracic region. [PDF]

open access: yesJ Appl Clin Med Phys
Abstract Background Anatomical changes during thoracic radiation therapy can alter dose delivery and compromise accuracy. Electronic portal imaging device (EPID)‐based in vivo dosimetry (IVD) enables noninvasive monitoring of these changes during treatment. Purpose This study quantitatively evaluated the impact of EPID‐based IVD in volumetric modulated
Tanaka K, Komori M.
europepmc   +2 more sources

Sensitivity and concordance study of an open source EPID-based linear accelerator test suite. [PDF]

open access: yesJ Appl Clin Med Phys
Abstract Background Electronic portal imaging devices (EPIDs) enhance linear accelerator (linac) quality assurance (QA) efficiency but are not universally used beyond patient‐specific IMRT QA. A multi‐institutional Consortium seeks to standardize linac QA utilizing an EPID‐based test suite.
Critchfield LC   +14 more
europepmc   +2 more sources

Radiological Loco-Regional Treatments for Cholangiocarcinoma: A Systematic Review of the Literature. [PDF]

open access: yesLiver Int
ABSTRACT Cholangiocarcinoma (CCA) is the second most common primary liver cancer and is being diagnosed with increasing frequency worldwide. We performed a systematic review on radiofrequency (RFA), microwave (MWA), irreversible electroporation (IRE), trans‐arterial chemoembolization (TACE) and selective internal radiation therapy (SIRT) in CCA. Thirty‐
Pallas D   +6 more
europepmc   +2 more sources

Commissioning of a near real-time in vivo film dosimetry system. [PDF]

open access: yesJ Appl Clin Med Phys
Abstract Background Accurate in vivo dosimetry is crucial for dose monitoring of cardiac implantable electronic devices (CIED) and for dose verification for special procedures such as total body irradiation (TBI) and total skin electron therapy (TSET). Purpose A new near real‐time in vivo dosimetry system using radiochromic films (RCF) is investigated ...
Yang Y   +8 more
europepmc   +2 more sources

Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy: a retrospective study [PDF]

open access: yesJournal of Yeungnam Medical Science, 2022
Background This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device.
Se An Oh   +4 more
doaj   +1 more source

Verification of IMRT and RapidArc Localized Prostate Cancer Treatment Plans Using EPID and Delta4 in vivo Dosimetry Methods [PDF]

open access: yesMiddle East Journal of Cancer, 2021
Background: Quality assurance for intensity modulated radiation therapy (IMRT) depends on the type of dosimetry system and its evaluation procedure. We can check both the intensity and distribution of each field as the required pretreatment verification ...
Moustafa Ahmed   +4 more
doaj   +1 more source

Assessment of the dosimetric performance of the Mobius3D against portal dose measurements in patient-specific quality assurance

open access: yesJournal of Medical Physics, 2023
Aim: The Mobius3D software addresses limitations lacking in measurement-based methods in patient-specific quality assurance (QA). The objective of this study was to validate its dosimetric performance against conventionally used portal dose measurements ...
Yasmine Joy M. Labagnoy   +3 more
doaj   +1 more source