Abstract Background Magnetic resonance–guided radiotherapy using 1.5 T MR‐LINAC systems introduces specific constraints for patient‐specific quality assurance (PSQA), requiring MR‐compatible dosimetric devices capable of accurate three‐dimensional dose verification.
Clement Chevillard +5 more
wiley +1 more source
Background A novel remote method for external dosimetric TPS-planned auditing of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for clinical trials using electronic portal imaging device (EPID) has been developed. The
Narges Miri +7 more
doaj +1 more source
Abstract Aim Current radiotherapy (RT) guidelines for Cardiac Implantable Electronic Devices (CIEDs) are largely based on clinical management strategies and retrospective reports. This systematic review adopts a medical physics perspective to provide a critical, quantitative analysis of the technical evidence required for developing robust safety ...
Tiziana Malatesta +15 more
wiley +1 more source
The effect of respiratory motion on electronic portal imaging device dosimetry [PDF]
AbstractThere is an increasing need to develop methods for in vivo verification of the delivery of radiotherapy treatments. Electronic portal imaging devices (EPID's) have been demonstrated to be of use for this application. The basic principle is relatively straightforward, the EPID is used to measure a two‐dimensional (2D) planar exit or portal dose ...
Fielding, Andrew +3 more
openaire +4 more sources
Electronic portal imaging devices (EPIDs) are extensively used for obtaining dosimetric information of pre-treatment field verification and in-vivo dosimetry for intensity-modulated radiotherapy (IMRT). In the present study, we have implemented the newly
Varatharaj C +5 more
doaj
Biomaterial‐integrated electroporation establishes a programmable therapeutic interface that coordinates electric‐field modulation, transient or irreversible membrane permeabilization, cargo stabilization, and immune remodeling. This Review highlights how nanocarriers, hydrogels, and bioelectronic interfaces expand electroporation from conventional ...
Binbin Ji +13 more
wiley +1 more source
Feasibility Study of Transit Dosimetry (TD) with an Electronic Portal Imaging Device (EPID) in volumetric arc therapy (VMAT) for head and neck cancer (HNC) [PDF]
Introduction: The progress in radiotherapy treatment modalities, such as Intensity Modulated Radiotherapy (IMRT) and Volumetric Arc Therapy (VMAT), introduces considerable complexity.
ARVIND DIUNDI +3 more
doaj +1 more source
A Review of the Australian MRI Linac Program: From Pie in the Sky to Research Milestone
ABSTRACT The Australian Magnetic Resonance Imaging (MRI) Linear Accelerator program (MRI linac) was a major research project that aimed to build and test a unique MRI linac prototype for cancer treatment. It aimed to improve radiotherapy anatomical targeting and explore physiological targeting. The purpose of this report is to summarise the development
Michael Bernard Barton +10 more
wiley +1 more source
The aim of this work was to evaluate results of a remote electronic portal imaging based dosimetric auditing method using Task-Group 218 clinical gamma evaluation criteria (3%,2 mm, 10% dose threshold).
Peter B. Greer +2 more
doaj +1 more source
Dual‐scan conformal cone‐beam CT for targeted image‐quality improvement using dynamic collimation
Abstract Background Cone‐beam computed tomography (CBCT) is routinely used for image guidance in radiation therapy, but conventional full‐field CBCT acquisition may expose anatomically irrelevant regions and generate substantial scatter, which degrades soft‐tissue contrast and limits the accuracy of target localization and adaptive radiotherapy ...