Results 51 to 60 of about 828,745 (178)
Abstract While acanthamoeba keratitis (AK) is a sight‐threatening corneal infection, a thorough comparison of the outcomes of therapeutic penetrating keratoplasty (PK) and therapeutic deep anterior lamellar keratoplasty (DALK) is lacking. We aimed to compare clinical outcomes of PK and DALK in AK.
Gábor Tóth +8 more
wiley +1 more source
Premium Intraocular Lens Selection in Patients With Glaucoma: A Clinical Review
ABSTRACT Glaucoma frequently coexists with cataract, but glaucomatous functional loss, ocular‐surface disease, anatomical abnormalities, and treatment‐related refractive variability may reduce tolerance of premium intraocular lenses. This narrative review critically appraises evidence relevant to lens selection in glaucoma. Central visual‐field status,
Zhihao Liu +3 more
wiley +1 more source
Anterior corneal, posterior corneal, and lenticular contributions to ocular aberrations [PDF]
Purpose: To determine the corneal surfaces and lens contributions to ocular aberrations.\ud \ud Methods: There were 61 healthy participants with ages ranging from 20 to 55 years and refractions –8.25 D to +3.25 D.
Mathur, Ankit +4 more
core +1 more source
A New Approach for the Calculation of Total Corneal Astigmatism Considering the Magnitude and Orientation of Posterior Corneal Astigmatism and Thickness [PDF]
Purpose: To evaluate a new method of calculation of total corneal astigmatism based on Gaussian optics and the power design of a spherocylindrical lens (C) in the healthy eye and to compare it with keratometric (K) and power vector (PV) methods.
Piñero, David P. +4 more
openaire +3 more sources
Reduced order modelling of air‐puff test for corneal material characterisation
Abstract Models of the fluid–structure interaction (FSI) model for the air‐puff test were analysed. Using Abaqus, the air‐puff test is applied to eyes with varying biomechanical parameters, such as material properties, corneal thickness, and radius.
Osama M. Maklad, Muting Hao
wiley +1 more source
3D‐Printed Corneal Substitutes: Materials, Fabrication, and Preclinical Progress
Successful clinical translation of 3D‐printed corneal substitutes relies on the interplay between the bioink properties, cellular component, and the fabrication process. These factors influence the critical properties of the construct, including optical transparency, mechanical stability, suture retention, that ultimately govern long‐term stromal ...
Shadi Moshayedi +4 more
wiley +1 more source
Understanding higher‐order aberrations in keratoconus
ABSTRACT Keratoconus is characterized by progressive thinning and increasing irregularity of the cornea, leading to substantial degradation in optical quality through the induction of both lower‐ and higher‐order aberrations (HOAs). In addition to inducing myopic and astigmatic refractive error, asymmetric corneal steepening generates complex optical ...
Gavin Swartz +3 more
wiley +1 more source
A graph showing no significant correlation between the magnitudes of anterior and posterior corneal astigmatism (Pearson correlation coefficient r = 0.1010, P = 0.2918) in eyes against-the-rule (ATR) anterior corneal astigmatism.
Kazutaka Kamiya (284327) +2 more
core +1 more source
Gender-differences in age-related changes of corneal astigmatism in Korean cataract patients
Background This cross-sectional study investigated age-related changes in anterior, posterior, and total corneal astigmatism and evaluated sex differences in corneal astigmatism with increasing age in cataract patients.
Hyojin Kim, Youngju An, Choun-Ki Joo
doaj +1 more source
Repositioning of Vertical Implantable Phakic Contact Lens
Vertical orientation of Implantable Phakic Contact Lens. ABSTRACT Implantable phakic contact lens (IPCL) V2.0 has a special patterned hole on the leading left corner to ensure correct orientation and positioning. Incorrect orientation is an absolute indication for repositioning.
Sushank Bhalerao +4 more
wiley +1 more source

