Aqueous fraction of <i>Alternanthera philoxeroides</i> as a biodegradable corrosion inhibitor of mild steel in sulphuric acid solution. [PDF]
Koju GM +5 more
europepmc +1 more source
Corrosion inhibition evaluation of Bauhinia purpurea extract mediated ZnO nanoparticles for carbon steel in acidic environment. [PDF]
Swathy O, Priya SS, Navada MK, Mulky L.
europepmc +1 more source
Potentiodynamic Polarization Behaviour of AISI Type 316 Stainless Steel in NaCl Solution
Potentiodynamic polarization behaviour of AISI type 316 SS in NaCl solution was investigated in terms of the potential scan rate effect. The critical pitting potential, E-pit, of the stainless steel appeared to be strongly dependent on the potential scan
Yongsun Yi, Changheui Jang, Yacine Addad
exaly +2 more sources
Potentiodynamic Polarization of Brass, Stainless and Coated Mild Steel in 1M Sodium Chloride Solution [PDF]
Enormous funds are spent on the protection of engineering components and structures annually as a result of corrosion. Degradation sets in, dueto electrochemical reaction that takes place between materials and the environment leading to reduced ...
Adeniran Afolalu +2 more
exaly +1 more source
Related searches:
Potentiodynamic Polarization Studies of Glycerin in Platinum Electrodes
Advanced Materials Research, 2015<span><p class="TTPAbstract"><span lang="EN-US">A three electrode system was used for the analysis of potentiodynamic polarization studies of glycerin in platinum electrodes. Particular attention was devoted to the estimation of diffusion coefficient of glycerin in platinum electrodes by the use of electrochemical techniques such as ...
Juan Carlos Beltrán-Prieto +2 more
openaire +1 more source
Improved Data Recording for Automatic Potentiodynamic Polarization Measurements
Corrosion, 1968Improvements in instrumentation for automatically plotting potentiodynamic polarization curves by using a scanning potentiostat, a logarithmic converter, and an X-Y recorder are described. An accessory circuit permits uninterrupted recording of polarization currents from 10−2 to 107 μa and virtually eliminates operator attention.
W. D. France, R. W. Lietz
openaire +1 more source
This paper reports the comparative evaluation of the corrosion behaviour of AZ31B magnesium alloy under immersion and potentiodynamic polarization test in NaCl solution at different chloride ion concentrations, pH value and exposure time.
Balasubramanian V +2 more
exaly +2 more sources
Corrosion testing by potentiodynamic polarization in various electrolytes
Dental Materials, 1992The effect of different electrolytes on the results from potentiodynamic polarization corrosion testing was studied for nine different dental alloys. In general, the difference in the results was greater between certain alloys using the same electrolyte than between the electrolytes with the same alloy.
openaire +2 more sources
Tutorial on Cyclic Potentiodynamic Polarization Technique
CORROSION 1998, 1998Abstract The cyclic potentiodynamic polarization technique provides a reasonable, rapid method for qualitatively predicting the propensity of an alloy to suffer localized corrosion in the form of pitting and crevice corrosion. Better and more accurate techniques are available for estimating general corrosion rates.
openaire +1 more source