Results 21 to 30 of about 4,867,816 (290)

Hawaii Deep Water Cable (HDWC) Program : cable overloadability study

open access: yes, 1986
The scope of this study is to determine the short term overload capability of Cable No. 116 in the event of the loss of one pole of the dc transmission system. Such a loss would result in the loss of 250 MW of transmitted power. This exceeds the spinning
Pirelli Cable Corporation and Societa Cavi Pirelli
core   +2 more sources

Analysis of Weak Section of Submarine Cable Inside J-Tube of Offshore Wind Farm

open access: yesIEEE Access
Global warming and environmental issues have necessitated ecofriendly energy generation from offshore wind farms. In this context, submarine cables for offshore wind farms and weak sections of the submarine cables inside the J-tube, which transmit power ...
Seung-Won Lee   +5 more
doaj   +1 more source

Space Charge Accumulation under Effects of Temperature Gradient and Applied Voltage Reversal on Solid Dielectric DC Cable [PDF]

open access: yes, 2009
A well-known fact of the existence and accumulation of space charge within the insulating material poses threat to the reliability in the operation of dc power cables.
Choo, Wilson   +5 more
core   +2 more sources

Artificial molecular machines and motors—Design and control of nanoscale motion

open access: yesFEBS Letters, EarlyView.
Molecules are constantly moving because of thermal fluctuations, but random motion alone cannot be exploited to perform directional tasks. Artificial molecular machines use chemical, electrical, or light energy to bias this motion. Molecular shuttles, rotary motors, and supramolecular pumps illustrate how nanoscale movement can be controlled and ...
Leonardo Andreoni, Alberto Credi
wiley   +1 more source

An image enhancement method for cable tunnel inspection robot

open access: yesAIP Advances
Influenced by multiple factors such as low light intensity, dispersed light, excessive dust, and excessive ambient noise inside cable tunnels, the images captured by cable tunnel inspection robots have shortcomings such as low contrast, low pixel values,
Yang Zhao   +3 more
doaj   +1 more source

Reliability Evaluation of Improved Sampling Method for Mechanical Test of Cable Insulation

open access: yesEnergies
Underground and submarine power cables are subjected to mechanical stress during installation and operation, which degrades the cable insulation and reduces the reliability of power transmission.
Seung-Won Lee   +5 more
doaj   +1 more source

Performance Analysis of Real-Scale 23 kV/60 MVA Class Tri-Axial HTS Power Cable for Real-Grid Application in Korea

open access: yesEnergies, 2020
Currently, various types of superconducting power cables are being developed worldwide, and research and development of a tri-axial high-temperature superconducting (HTS) power cable are underway.
Seok-Ju Lee   +5 more
doaj   +1 more source

Genetic dissection of human ABCE1 in yeast reveals separable requirements for ribosome recycling and suppression of aberrant reinitiation

open access: yesFEBS Open Bio, EarlyView.
Human ABCE1 cannot functionally replace its yeast ortholog. Yeast–human chimera analysis identified NBD1 as a major interspecies barrier. Genetic screening yielded hABCE1 revertants that rescue yeast viability but fail to suppress aberrant translation reinitiation in the 3′ UTR.
Eriko Nakata   +3 more
wiley   +1 more source

The Role of Calcitonin Gene‐Related Peptide in High‐Altitude Headache: A Prospective Field Study

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective High‐altitude headache (HAH) is a common neurological condition associated with rapid ascent to high altitude. The pathophysiological mechanisms underlying HAH remain incompletely understood. Calcitonin gene‐related peptide (CGRP), a neuropeptide implicated in migraine pathophysiology, may play a key role in the pathophysiology of ...
Roman Schniepp   +4 more
wiley   +1 more source

Enhanced Clustering of DC Partial Discharge Pulses Using Multi-Level Wavelet Decomposition and Principal Component Analysis

open access: yesEnergies
Partial discharge (PD) is a critical indicator of insulation degradation in high-voltage DC systems, necessitating accurate diagnosis to ensure long-term reliability.
Sung-Ho Yoon   +5 more
doaj   +1 more source