Results 21 to 30 of about 6,822,454 (350)

Closed-Form Expressions for the Analysis of Wave Propagation in Overhead Distribution Lines

open access: yesEnergies, 2020
The calculation of the influence of the imperfect earth on overhead conductors is an important issue in power system analysis. Rigorous solutions contain infinite integrals; thus, due to their complex form, different simplified closed-form expressions ...
Theofilos A. Papadopoulos   +3 more
doaj   +1 more source

Transient Voltage-Reactive Power Modeling of Offshore Wind Power Collection and Transmission System with AC Cables and Characteristic Analysis

open access: yesZhongguo dianli, 2022
The transient overvoltage at the sending terminal of the offshore wind power collection and transmission system with AC cables threatens the safe and stable operation of the system.
Yanxia SUN, Shiwen FANG, Zhen LI
doaj   +1 more source

Research on the Electric Field Distribution and Structure Optimizing  of Integral Prefabricated Joint and Taped Joint

open access: yesJournal of Harbin University of Science and Technology, 2018
Integral prefabricated joint and taped joint are two kinds of widely used cable joint.Because of the different structure and conductivity of insulation, there is great difference in the electric field distribution between the two kinds of joints .In this
CHEN Zhen-xin   +7 more
doaj   +1 more source

Experimental testing and evaluation of coating on cables in container fire test facility

open access: yesNuclear Engineering and Technology, 2022
Fire tests were conducted on cables using fire-retardant paint employed in nuclear power plants that transmit electrical power, control and instrument signals. The failure criteria of various power and control cables coated with fire retardant coating at
P. Babu Aurtherson   +4 more
doaj   +1 more source

Design of Power Cable Lines Partially Exposed to Direct Solar Radiation—Special Aspects

open access: yesEnergies, 2020
Power cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially ...
Stanislaw Czapp   +2 more
doaj   +1 more source

A similarity-based framework for incipient fault detection in underground power cables

open access: yes, 2021
Incipient faults are known as the faults mainly occurring on the junctions of underground power cables. Clearing quickly, these faults are difficult to detect by conventional protection equipment, leading to insulation degradation and permanent fault in ...
H. Samet   +4 more
semanticscholar   +1 more source

Insulation Performance Analysis of Field Aged and New MV XLPE Cables Using Various Diagnostic Techniques [PDF]

open access: yesE3S Web of Conferences, 2021
Cross-linked polyethylene (XLPE) cables are widely used in the distribution and transmission networks of power systems. The insulation materials of these cables are stressed by the over voltages and are also exposed to various environmental conditions ...
Al-Onazi Yousef   +3 more
doaj   +1 more source

Concepts and Methods to Assess the Dynamic Thermal Rating of Underground Power Cables

open access: yes, 2021
With the increase in the electrical load and the progressive introduction of power generation from intermittent renewable energy sources, the power line operating conditions are approaching the thermal limits. The definition of thermal limits variable in
D. Enescu   +4 more
semanticscholar   +1 more source

Research on same-phase parallel connection technology of submarine cable

open access: yesEnergy Reports, 2023
Offshore wind power generation has been developed rapidly. In order to improve the efficiency of offshore wind power generation, this paper studies the parallel connection of two same-phase cables of two-circuit of submarine cables.
Ruiyong Zhang   +4 more
doaj   +1 more source

Evaluation of simplified heat transport for power cables in pipes [PDF]

open access: yes, 2023
Power cables in air- or water-filled pipes are the thermal bottleneck in many installations. Some parts of the industry reduce the complexity of their numerical models by combining conduction, convection, and surface-surface radiation into an effective ...
Hellesø, Svein Magne   +3 more
core  

Home - About - Disclaimer - Privacy