Results 31 to 40 of about 195,242 (204)
Single phase line‐broken (SPLB) fault is one kind of high impedance fault (HIF). When a SPLB fault occurs, there are four scenarios: SPLB fault with neither side conductors grounded (SPLB‐NSCG), with source side conductor grounded only (SPLB‐SSCG), with ...
Zhongxue Chang +4 more
doaj +1 more source
Research on evaluation method of energy supply reliability of regional energy Internet [PDF]
This paper studies the reliability evaluation technology of regional energy Internet and represents a reliability evaluation method considering the optimal load reduction strategy. The application scenario of regional Energy Internet with power system as
Li Pengli +4 more
doaj +1 more source
Wind turbine condition assessment through power curve copula modeling [PDF]
Power curves constructed from wind speed and active power output measurements provide an established method of analyzing wind turbine performance. In this paper it is proposed that operational data from wind turbines are used to estimate bivariate ...
Galloway, Stuart +2 more
core +1 more source
Island division and multi-objective network reconstruction considering power flow entropy [PDF]
Modern power system can identify component faults, isolate faults and resume operation quickly. In view of the problem that the distribution of line load in distribution network is not reasonable and it is easy to fall into the self-organized critical ...
Yang Linghui +6 more
doaj +1 more source
Short circuit study of fixed speed wind turbines with STATCOM in distribution networks [PDF]
The increased penetration of wind farm in distribution networks has brought changes in the performance of the whole system. Such disadvantages when connecting one of these distributed generation sources is reduced voltage and power stability of the AC ...
Darwish, M, Naain, MM, Zobaa, AF
core +1 more source
Voltage Multistability and Pulse Emergency Control for Distribution System with Power Flow Reversal [PDF]
High levels of penetration of distributed generation and aggressive reactive power compensation may result in the reversal of power flows in future distribution grids.
Nguyen, Hung D., Turitsyn, Konstantin
core +2 more sources
An analysis of the Medium Voltage (MV)electricity power distribution network operated by Cameroon’s AES-SONEL company shows that losses are very high due to energy which is produced but not distributed and that the duration of power interruptions as a ...
Thomas Tamo Tatietse, Joseph Voufo
doaj +1 more source
Traveling Wave Energy Analysis of Faults on Power Distribution Systems
This paper explores the most important factors that define the Traveling Wave (TW) propagation on distribution systems. The factors considered in this work are: the distance to the fault location, the fault type, and the crossing of system elements (such
Miguel Jiménez-Aparicio +2 more
doaj +1 more source
Advanced FLISR With Intentional Islanding Operations in an ADMS Environment Using GridAPPS-D
An advanced distribution management system (ADMS) is a software platform that supports grid management and decision support applications to address the growing operational challenges faced by power distribution systems to ensure reliable, resilient, and ...
Shiva Poudel +3 more
doaj +1 more source
Fault-Location Scheme for Power Distribution System with Distributed Generation [PDF]
This paper presents a novel fault-location scheme for unbalanced power distribution system in the presence of distributed generation (DG). The proposed scheme first identifies the possible fault locations using a new formulation of the impedance-based method.
Alwash, S.F. +2 more
openaire +2 more sources