Results 91 to 100 of about 96,152 (211)

High-Voltage High-Capacity Active Filter Technology for High Voltage DC Converter Station [PDF]

open access: yesDianli jianshe
[Objective] High-voltage direct current transmission technology is a core technical method for optimizing resource allocation in China. Traditional high-voltage direct-current transmission technology has many drawbacks, such as a large footprint and ...
WANG Ling, MA Weimin, JI Yiming, LI Ming, WU Fangjie, XU Ying, DU Xiaolei, ZHANG Xiujuan
doaj   +1 more source

Grid voltage sensorless control of a single‐phase shunt hybrid active power filter

open access: yesIET Power Electronics
Here, a grid voltage sensorless control of an LCL‐filtered LC‐tuned single‐phase shunt hybrid active power filter (HAPF) is proposed, which offers high‐quality harmonic current compensation with low hardware requirements. An estimation algorithm replaces
Mohammad‐Sadegh Karbasforooshan   +1 more
doaj   +1 more source

Synchronous reference frame fundamental method in shunt active power filter for mitigation of current harmonics [PDF]

open access: yes, 2017
This research presents compensation of current harmonic disturbance in power system network using shunt active power filter. In this paper, harmonic extraction using Synchronous Reference Frame Fundamental technique (SRFF) was investigated for three ...
Mohd Radzi, Mohd Amran, Musa, Suleiman
core  

Harmonic Analysis of Transmission Scheme for Offshore Wind Farms Based on Diode Rectifier Unit

open access: yesEngineering Reports
The diode rectifier unit (DRU) based transmission scheme is the technology hotspot in the field of transmission scheme for offshore wind farms. DRU not only realizes the rectification but also brings harmonic problems to the system.
Qing Chen   +4 more
doaj   +1 more source

A Blind Interference Canceling Technique for Two-Stage Harmonic Rejection in Down-mixers [PDF]

open access: yes, 2008
This paper presents practical experiments on a harmonic rejection down-mixer, which offers up to 75 dB of harmonic rejection, without an RF filter. The down-mixer uses a two-stage approach; the first stage is an analog multi-path/multiphase harmonic ...
Klumperink, E.A.M.   +2 more
core   +1 more source

Harmonics Mitigation of Industrial Power System Using Passive Filters [PDF]

open access: yesMehran University Research Journal of Engineering and Technology, 2012
With the development of modern industrial technology a large number of non-linear loads are used in power system, which causes harmonic distortion in the power system. At the same time the power quality and safe operation becomes inferior.
Zubair Ahmed Memon   +2 more
doaj  

EFISIENSI DAYA PADA BEBAN DINAMIK DENGAN KAPASITOR BANK DAN FILTER HARMONIK [PDF]

open access: yes, 2011
Electrical power efficiency can be improved by improving power quality. Good power quality can be done by improving: the voltage drop, power factor, power loss and reduce harmonics. Use rectifier 3 phasa causing great harmonics.
Bambang Wahyono, Bambang   +2 more
core  

High photon flux table-top coherent extreme ultraviolet source

open access: yes, 2014
High harmonic generation (HHG) enables extreme ultraviolet radiation with table-top setups. Its exceptional properties, such as coherence and (sub)-femtosecond pulse durations, have led to a diversity of applications.
Hoffmann, Armin   +8 more
core   +1 more source

POWER SYSTEM HARMONIC REDUCTION USING SHUNT ACTIVE FILTER

open access: yesInternational Journal of Research in Engineering and Technology, 2014
This paper shows the method of improving the power quality using shunt active power filter. The proposed topic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is from hysteresis current controller techniques. With the all these element shunt active power filter reduce the
openaire   +1 more source

Method for determining the harmonic contribution of consumer installations based on the application of passive filters

open access: yesIET Generation, Transmission & Distribution
The paper presents a new method for estimating the contribution of distortion sources based on the application of passive harmonic filters. The method does not require the measurement of harmonic network impedance and is based on the measurement of ...
Aleksandr Skamyin
doaj   +1 more source