Results 11 to 20 of about 7,341,189 (200)

Challenges of developing a power system with a high renewable energy proportion under China’s carbon targets

open access: yesiEnergy, 2022
For China, one of its most important commitments is to realize its “3060” targets of achieving a CO2 emission peak by 2030 and carbon neutrality by 2060.
Jianbo Guo   +5 more
doaj   +1 more source

Research on Maintenance Strategies for Different Transmission Sections to Improve the Consumption Rate Based on a Renewable Energy Production Simulation

open access: yesEnergies, 2022
Renewable energy consumption is one of the most important factors in meeting the goal of “30 and 60” in China. However, the maintenance of the transmission section affects the amount of generation transfer, further affecting the consumption of renewable ...
Xiaojing Hu   +7 more
doaj   +1 more source

An Incentive-Compatible Frequency Regulation Market for Flexible Resources in Microgrid

open access: yesIEEE Access, 2023
Frequency regulation services can be provided by emerging flexible resources such as electric vehicles and energy storage which can rapidly adjust the output in response to regulation signals, as long as there is an effective market to provide proper ...
Han Zhou   +5 more
doaj   +1 more source

Cooling of Steam Turbine Exhaust Hood and Last Stage Blade [PDF]

open access: yesMATEC Web of Conferences, 2023
This paper describes a novel semi-numerical method of water droplets path lines calculation in steam turbine axial exhaust hood 2D space. The axial velocity profile of steam as well as droplets evaporation are taken into account.
Hoznedl Michal   +5 more
doaj   +1 more source

Root-Mean Square Model of Three-Phase Photovoltaic Inverter for Unbalanced Fault

open access: yesIEEE Open Access Journal of Power and Energy, 2020
The feed-in tariff, introduced in 2012, led to a significant increase in Photovoltaics (PVs) throughout Japan. About half of PVs are three-phase PVs that are connected to low voltage or medium voltage networks.
Hayato Satoh   +3 more
doaj   +1 more source

Practical experience in monitoring low-frequency oscillations at electric power station of United Power System of Russia [PDF]

open access: yesE3S Web of Conferences
The development of the Wide Area Measurement System (WAMS) in the United Power System of Russia has provided the opportunity to use phasor measurement unit (PMU) data to solve practical problems in operational dispatch management [1].
Govorun Mikhail   +4 more
doaj   +1 more source

Research on the electrical performance variation characteristics of internal damp roof arrester of EMU

open access: yesEnergy Reports, 2022
In order to study the reason of performance deterioration of roof arrester, this paper conduct the disassembly inspection of the burst arrester, and conducts the SEM test and EDS test to the valve plates, and the microscopic variation characteristics of ...
Shenghui Wang   +4 more
doaj   +1 more source

Research on the Accurate Measurement and Analysis of Carbon Emissions by Carbon Real Measurement [PDF]

open access: yesE3S Web of Conferences, 2023
The practice of carbon emission accurate measurement system application scenario of carbon electricity coupling and carbon real measurement is carried out, based on the carbon constraint background, the whole process of carbon production and emission is ...
Wang Hanyun   +5 more
doaj   +1 more source

Reactive Power Control in Power System using Modified UPFC [PDF]

open access: yes, 2017
The power system is a exceptionally nonlinear system that works in an always showing signs of change condition, loads, generator yields, topology and key working parameters changes consistently.
Bilal, E. M. (Engr)   +2 more
core   +1 more source

Experience in implementing the algorithm for emergency control system of unloading in case of overload in terms of power based on synchrophasor angle [PDF]

open access: yesE3S Web of Conferences
An algorithm for automatic unloading during a power overload is described. It is based on measurement of the phase angle between voltages on the Tyumen - Ural power transmission line, which is determined by information from phasor measurement units.
Govorun Mikhail   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy