Results 21 to 30 of about 22,361,033 (242)

Hazard evaluation of ground potential difference within grounding grid on personal safety under impulse current

open access: yesIET Science, Measurement & Technology, 2021
Due to the impedance characteristic of conductor, the ground potential rise is different within grounding grid when impulse current is injected. When staff touches objects with different GPR at the same time, the GPD will be applied to human body ...
Chun Li   +5 more
doaj   +1 more source

Optimal Outage Management Model Considering Emergency Demand Response Programs for a Smart Distribution System

open access: yesApplied Sciences, 2020
In this paper, a novel smart outage management system considering Emergency Demand Response Programs (EDRPs) and Distributed Generations (DGs) denoted as SOMSDGsEDRPs is proposed.
Sobhan Dorahaki   +2 more
doaj   +1 more source

Extremely low frequency‐based faulty line selection of low‐resistance grounding system

open access: yesIET Generation, Transmission & Distribution, 2021
The single‐phase‐to‐ground faulty line selection methods based on the signals of the frequency above 10 Hz has a low discrimination of fault characteristic signal and characteristic signal may be covered by noise in cases of high‐resistance fault.
Qing Chen   +6 more
doaj   +1 more source

Distributed Power-Generation Systems and Protection [PDF]

open access: yesProceedings of the IEEE, 2017
Continuously expanding deployments of distrib¬uted power-generation systems (DPGSs) are transforming the conventional centralized power grid into a mixed distributed electrical network. The modern power grid requires flexible energy utilization but presents challenges in the case of a high penetration degree of renewable energy, among which wind and ...
Frede Blaabjerg   +3 more
openaire   +1 more source

Instantaneous Specific Protection Method Against Faulty Synchronizations of Synchronous Machines

open access: yesIEEE Access, 2021
The probability of faulty synchronization of a generator is very small, but not impossible. The main cause of a faulty synchronization is due to wiring errors caused during maintenance or commissioning when voltage transformer and synchronizing equipment
Pengfei Tian   +3 more
doaj   +1 more source

Impacts of protection system misoperation on the reliability of Turkish National Power Transmission System [PDF]

open access: yes, 2011
State Grid EPRI (NARI Group);Sifang Automation Co., Ltd;Guodian Nanjing Automation Co., Ltd;Xuji Group Co.;Dongfang Electronics Co., Ltd2011 International Conference on Advanced Power System Automation and Protection, APAP 2011 -- 16 October 2011 through
Ilisu I.   +5 more
core   +1 more source

Identification of Critical Transmission Lines in Complex Power Networks

open access: yesEnergies, 2017
Growing load demands, complex operating conditions, and the increased use of intermittent renewable energy pose great challenges to power systems. Serious consequences can occur when the system suffers various disturbances or attacks, especially those ...
Ziqi Wang   +4 more
doaj   +1 more source

Differential protection strategy for distribution network based on 5G communication

open access: yesIET Generation, Transmission & Distribution, 2023
With the high penetration of distributed generation and gradual increase in loop network structures, existing over‐current protection in distribution networks is difficult to apply. The use of current differential protection has become an ideal solution,
Liu Zhiren   +6 more
doaj   +1 more source

Impact of converter interface type on the protection requirements for DC aircraft power systems [PDF]

open access: yes, 2012
The utilization of converter interfaces has the potential to significantly alter the protection system design requirements in future aircraft platforms.
Burt, Graeme   +3 more
core   +4 more sources

Standardization of power system protection settings using IEC 61850 for improved interoperability [PDF]

open access: yes, 2013
One of the potential benefits of smart grid development is that data becomes more open and available for use by multiple applications. Many existing protection relays use proprietary formats for storing protection settings.
Catterson, Victoria   +5 more
core   +4 more sources

Home - About - Disclaimer - Privacy