Results 41 to 50 of about 256,126 (170)

Coordinated Suppression Method of Fault Current for DC Grid with Novel Dissipative Resistors Topology

open access: yesCSEE Journal of Power and Energy Systems
A DC grid based on half-bridge modular multilevel converters (HB-MMC) is a feasible means to realize the friendly grid connection of renewable energy.
Shouqi Jiang   +5 more
doaj   +1 more source

Power System Simulator for Realistic Dispatcher Training

open access: yesIFAC Proceedings Volumes, 1989
Abstract The paper describes a training system which is incorporable into existing system control centers. The aspects considered for the system design are presented: - the man-machine-interface for training is the same as for real operation - the power system behaviour is realistically simulated - there is no interference with the actual
K. Heuck, A. Huber, E. Reuter
openaire   +1 more source

Interactions between two grid PMSG wind turbines: A perspective on subsynchronous oscillations

open access: yesInternational Journal of Electrical Power & Energy Systems
Subsynchronous oscillation (SSO) in grid-connected permanent magnet synchronous generators (PMSGs) is a complex dynamic behavior influenced by multiple factors.
Cheng Yang   +5 more
doaj   +1 more source

Peer-to-peer energy trading with energy trading consistency in interconnected multi-energy microgrids: A multi-agent deep reinforcement learning approach

open access: yesInternational Journal of Electrical Power & Energy Systems
Multi-energy microgrid technology is an essential for addressing the diversification of energy demand and local consumption of renewable energy sources.
Yang Cui   +5 more
doaj   +1 more source

Development of Advanced Power System Analogue Simulator

open access: yesIEEJ Transactions on Power and Energy, 1990
AbstractThe digital simulation method has been utilized to analyze phenomena in power systems. Since different algorithms can be applied, depending on the phenomena to be analyzed, digital simulation allows for high‐precision analysis.However, it also has a disadvantage: it produces continuous phenomena which occur in actual systems only fragmentarily.
Hirosuke Doi   +4 more
openaire   +2 more sources

Analysis and suppression of high-frequency oscillation in wind farm-MMC-HVDC interconnected system considering distribution characteristics of submarine cables

open access: yesInternational Journal of Electrical Power & Energy Systems
With the large-scale development of offshore wind power, modular multilevel converter-based high-voltage direct current (MMC-HVDC) has emerged as a pivotal grid integration solution, yet it is constrained by high-frequency oscillation issues in power ...
Yanxu Wang   +5 more
doaj   +1 more source

LLM-Powered User Simulator for Recommender System

open access: yesProceedings of the AAAI Conference on Artificial Intelligence
User simulators can rapidly generate a large volume of timely user behavior data, providing a testing platform for reinforcement learning-based recommender systems, thus accelerating their iteration and optimization. However, prevalent user simulators generally suffer from significant limitations, including the opacity of user preference modeling and ...
Zijian Zhang 0009   +8 more
openaire   +2 more sources

Coordinated control strategy for MMC-CLCC considering AC voltage support and active power transmission

open access: yesInternational Journal of Electrical Power & Energy Systems
The hybrid HVDC transmission system employing the Modular Multilevel Converter (MMC) at the sending end and the Controllable Line-Commutated Converter (CLCC) at the receiving end offers advantages such as avoiding commutation failures and providing ...
Weiru Wang   +5 more
doaj   +1 more source

Physical propagation and anomaly identification of transformer with HVDC&RTTS stray current invasion

open access: yesInternational Journal of Electrical Power & Energy Systems
Aiming at the operation stability of the transformer with stray current invasion, the evolution and propagation of multiple information is investigated in this paper.
Chao Pan   +5 more
doaj   +1 more source

Establishment of safety power range and subsequent commutation failure suppression strategy for hybrid cascaded HVDC system

open access: yesInternational Journal of Electrical Power & Energy Systems
The hybrid cascaded high-voltage direct current (HC-HVDC) system integrates the benefits of both LCC and MMC technologies. However, the inverter LCC is prone to suffer subsequent commutation failure (SCF) when an AC fault occurs. Therefore, a coordinated
He Wang   +4 more
doaj   +1 more source