Results 61 to 70 of about 108,225 (350)
Short circuit study of fixed speed wind turbines with STATCOM in distribution networks [PDF]
The increased penetration of wind farm in distribution networks has brought changes in the performance of the whole system. Such disadvantages when connecting one of these distributed generation sources is reduced voltage and power stability of the AC ...
Darwish, M, Naain, MM, Zobaa, AF
core +1 more source
It is shown that laser ablation pretreatment under oxygen‐free conditions enables copper–aluminium bonding at significantly lower deformation degrees and improved properties compared to mechanical brushing. Laser ablation further increases interface contact area and induces favourable residual stress states and microstructural compatibility ...
Khemais Barienti +11 more
wiley +1 more source
Due to the complex structure of hybrid cascaded DC transmission systems, a DC line protection scheme based on boundary transient power direction is proposed to enhance protection adaptability. First, the smoothing reactor serves as the boundary, enabling
WANG Shuzheng +4 more
doaj +1 more source
Fault classification in power systems using EMD and SVM
In recent years, power quality has become the main concern in power system engineering. Classification of power system faults is the first stage for improving power quality and ensuring the system protection.
N. Ramesh Babu, B. Jagan Mohan
doaj +1 more source
International White Book on DER Protection : Review and Testing Procedures [PDF]
This white book provides an insight into the issues surrounding the impact of increasing levels of DER on the generator and network protection and the resulting necessary improvements in protection testing practices.
Abdulhadi, Ibrahim Faiek +7 more
core
Stabilization of L‐PBF Ni50.7Ti49.3 under low‐cycle loading was investigated. Recoverable strain after cycling was dependent on the amount of applied load. Recovery ratio was 53.4% and 35.1% at intermediate and high load, respectively. The maximum total strain reached 10.3% at a high load of 1200 MPa.
Ondřej Červinek +5 more
wiley +1 more source
Protection challenges in future converter dominated power systems [PDF]
Converter interfaces, used to connect renewable energy sources, HVDC links and infeeds to the power system, will bring significant changes to the behaviour of power systems in the future, particularly in Great Britain (GB).
Booth, Campbell +5 more
core +1 more source
Creep experiments at 900°C on coarse‐grained steel‐ceramic composites containing recycled magnesia reveal that higher ceramic volume fractions significantly enhance the creep resistance. Detailed EBSD investigations identify subgrain formation in the steel matrix as the dominant deformation mechanism.
Moritz Müller +6 more
wiley +1 more source
An equivalent circuit for the evaluation of cross-country fault currents in medium voltage (MV) distribution networks [PDF]
A Cross-Country Fault (CCF) is the simultaneous occurrence of a couple of Line-to-Ground Faults (LGFs), affecting different phases of same feeder or of two distinct ones, at different fault locations.
Gatta, Fabio Massimo +3 more
core +1 more source
Influence of an Argon/Silane Atmosphere on the Temperature of a Thermal Plasma
The influence of a silane‐doped argon atmosphere on the chemical composition and temperature of a thermal nontransferring argon plasma is investigated using optical emission spectroscopy. As a result of the high amount of free electrons resulting from the stepwise ionization and dissociation of the silane molecule, even a silane addition of 0.01 vol ...
Lena Kreie +4 more
wiley +1 more source

