Results 21 to 30 of about 148,089 (265)

Analysis of Power Network for Line Reactance Variation to Improve Total Transmission Capacity

open access: yesEnergies, 2016
The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks.
Ikram Ullah   +2 more
doaj   +1 more source

Investigating the impact of a dynamic thermal rating on wind farm integration

open access: yesIET Generation, Transmission & Distribution, 2023
With an increased focus on renewable power generation, dynamic thermal ratings of various power equipment are being investigated to connect the new intermittent generation to the grid without needing to replace existing infrastructure.
Leanne Dawson, Andrew M. Knight
doaj   +1 more source

Gut microbiome and aging—A dynamic interplay of microbes, metabolites, and the immune system

open access: yesFEBS Letters, EarlyView.
Age‐dependent shifts in microbial communities engender shifts in microbial metabolite profiles. These in turn drive shifts in barrier surface permeability of the gut and brain and induce immune activation. When paired with preexisting age‐related chronic inflammation this increases the risk of neuroinflammation and neurodegenerative diseases.
Aaron Mehl, Eran Blacher
wiley   +1 more source

Modulation of Homer1 EVH1 domain internal dynamics by putative autism‐associated mutations

open access: yesFEBS Letters, EarlyView.
The putative autism‐associated M65I and S97L variants of the EVH1 domain of the postsynaptic scaffold protein Homer1 do not exhibit substantial changes in their overall structure or partner binding. Both of them, but especially the M65I variant, show altered internal dynamics relative to the wild‐type domain on the μs‐ms timescale, indicated by the ...
Fanni Farkas   +6 more
wiley   +1 more source

Mechanical Calculation of Power Lines and Strands in Overhead Transmission Lines

open access: yesMATEC Web of Conferences, 2016
This paper discusses the issue of shape and stress of overhead transmission lines. It fully considers that the conductor is subjected to axial force, shear, bending moment simultaneousiy. And the flat wire is basically in the elastic range.
Li Yongping, Liu Yu, Zhang Jibin
doaj   +1 more source

Detection of Arc in the Transmission Power Lines

open access: yesInternational Journal of Energy Engineering, 2011
Automatic one-and three-phase re-closing power lines, after short circuit shutdown, is a very effective way to improve the reliability of power delivery. Re-closing while the fault is not cleared can be dangerous for some electrical appliances. To prevent re-closing of a short circuit a method allowing stable arc detection has developed.
openaire   +2 more sources

Power-Line Communications: Smart Grid, Transmission, and Propagation [PDF]

open access: yesJournal of Electrical and Computer Engineering, 2013
1 School of Informatics, College of Informatics and Virtual Education, University of Dodoma, P.O. Box 490, Dodoma, Tanzania 2 Electrical Engineering Department, Faculdade de Engenharia, Federal University of Juiz de Fora, Campus Universitario, 36 033 330 Juiz de Fora, MG, Brazil 3Wireless and Power Line Communications Lab, Universita di Udine, 33100 ...
Justinian Anatory   +3 more
openaire   +3 more sources

From mice to humans—divergent strategies for intestinal homeostasis and regeneration

open access: yesFEBS Letters, EarlyView.
Recent advances such as organoid genome editing, xenotransplantation, imaging, and whole‐genome sequencing have enabled direct studies of human intestinal stem cells (ISCs). These studies reveal species‐specific features, including slower ISC proliferation, distinct injury responses, slower somatic mutation accumulation in humans, and an inverse ...
Keiko Ishikawa   +2 more
wiley   +1 more source

A microstrip quad‐band power divider based on stepped impedance coupled lines

open access: yesIET Microwaves, Antennas & Propagation
A novel design of quad‐band power divider (PD) is proposed in this brief. By introducing the stepped impedance coupled lines, the frequency offset and power loss caused by dispersion are effectively reduced.
Xinhuai Wang   +6 more
doaj   +1 more source

Heterozygous loss‐of‐function alleles associate the conserved 3′‐5′ exoribonuclease EXOSC10 with hypersensitivity to the anticancer drug 5‐fluorouracil

open access: yesMolecular Oncology, EarlyView.
EXOSC10, an essential nuclear RNA exosome‐associated 3′‐5′ exoribonuclease, is inhibited by the anticancer drug 5‐fluorouracil (5‐FU), and EXOSC10 depletion increases 5‐FU sensitivity. The colon‐cancer variant EXOSC10S402T, located in a proteolysis motif, is stable and nuclear but nonfunctional in vivo.
Radhika Sain   +10 more
wiley   +1 more source