Results 261 to 270 of about 667,676 (300)
Some of the next articles are maybe not open access.

C.A.E. Software for Transmission Protection System: Puget Power Experience

IEEE Transactions on Power Delivery, 1987
One major concern of a protection engineer is to achieve successful coordination of all relays in a transmission network. This tedious and laborious process is usually accomplished manually at present. In this paper we present the results of a Computer-Aided Protection System based on our experimentation with the entire 115 kV transmission network of ...
S. S. Venkata   +4 more
openaire   +1 more source

Active power differential algorithm for protection of transmission lines

PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376), 2003
A differential algorithm for phase selective detection of high impedance single-phase-to-ground faults (HIF) on high voltage lines is presented. It is based on the recognition of the fundamental frequency active power consumption of a resistive fault.
F. Oechsle   +3 more
openaire   +1 more source

Performance analysis of power differential based transmission line protection

2017 International Conference on Energy, Communication, Data Analytics and Soft Computing (ICECDS), 2017
This paper deals with investigation of novel fault detection for the protection of transmission line. Conceptually the difference of the average quantities for phase active power entering and leaving the lines are compared Computation of these quantities is carried out via simulating a tie line connecting two power system networks using MATLAB.
Surabhi Deotale, Ashish A. Dongre
openaire   +1 more source

A backup wide‐area protection technique for power transmission network

IEEJ Transactions on Electrical and Electronic Engineering, 2017
This paper proposes a wide‐area backup protection technique for transmission lines using a limited number of synchronized phasor measurement units. A binary integral linear programming is used for optimal placement of phasor measurement units to achieve fault observability.
Hany Elghazaly, Ahmed Emam, Ahmed Saber
openaire   +1 more source

Some observations for distance protection of power transmission lines

IEEE Southeastcon 2009, 2009
This paper presents some observations related to distance protection for power system transmission lines. Classical distance protection relays adopt the line terminal voltage and line current to calculate the distance between the fault and the relay location and then make a decision on whether a tripping signal should be issued and, if so, what the ...
openaire   +1 more source

Galvanic Cathodic Protection for Power Transmission Tower Grillage Foundations

Materials Performance, 2016
Cathodic protection (CP) of underground steel structures is a mature technology for structures with simple geometries, such as pipelines and storage tanks. Nevertheless, this technology is not well-adapted to structures with irregular geometries, where application of conventional anode bed designs are formidable due to the interplay of geometrical and ...
Peyman Taheri, Mehrooz Zamanzadeh
openaire   +1 more source

An Integrated Boundary Protection Scheme for Power Transmission Line Systems

International Journal of Emerging Electric Power Systems, 2008
This paper presents an integrated boundary protection scheme for power transmission line systems. The scheme combines the latest developments in two areas of power system protection, the transient based protection and the integrated protection. In the proposed scheme, an integrated relay based on the boundary protection principle installed at a ...
Zhiqian Bo   +4 more
openaire   +1 more source

Protection of Power Transmission Lines Using Intelligent Hot Spot Detection

2019 Fifth International Conference on Electrical Energy Systems (ICEES), 2019
This paper manages discovery of the problem areas in power transmission lines in an optimized thermal picture processing method. The technology followed in this research was automated hot spot detection base on image processing with hybrid algorithm. At every point of time video is changed over into number of picture by utilizing MATLAB coding.
Sriram Anbalagan, T. D. Sudhakar
openaire   +1 more source

Modeling of power transmission and stress grading for corona protection

Computational Mechanics, 2017
zbMATH Open Web Interface contents unavailable due to conflicting licenses.
T. I. Zohdi, B. E. Abali
openaire   +1 more source

Experimental evaluation of power differential relay for transmission line protection

2009 IEEE/PES Power Systems Conference and Exposition, 2009
An experimental evaluation of a power differential relay is conducted and the results are described. The experimental setup consists of a generator connected to the network via a transmission line protected by the power deferential relay. The relay input signals, fundamental active and reactive powers, are locally computed from the complex product of ...
H. A. Darwish   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy