Results 71 to 80 of about 666,590 (300)

Influence of Flexibilizers on the Thermal and Combustion Properties of Soundproof Enclosures in Ultrahigh Voltage Converter Transformer Equipment

open access: yesFire
Soundproof enclosures are essential components in ultra-high voltage converter transformer equipment. However, conventional designs pose considerable fire risks, as they may impede fire suppression efforts in case of equipment failure. This study adopted
Jiaqing Zhang   +4 more
doaj   +1 more source

Power Transmission Clamps for Analysis and Protection of Electrical Transmission Lines

open access: yes, 2019
The invention disclosed is type of electronic actuator which tensions and compresses the grid transmission wires so as to avoid the sagging of the wires during high temperature environment. The invention also helps in reducing the vibration of the wires which increases the life of the wires respectively.
openaire   +1 more source

EBSD Study of Creep‐Induced Lattice Misorientation in MgO‐Particle‐Reinforced Austenitic Steel Composites

open access: yesAdvanced Engineering Materials, EarlyView.
Creep experiments at 900°C on coarse‐grained steel‐ceramic composites containing recycled magnesia reveal that higher ceramic volume fractions significantly enhance the creep resistance. Detailed EBSD investigations identify subgrain formation in the steel matrix as the dominant deformation mechanism.
Moritz Müller   +6 more
wiley   +1 more source

Experimental study on enhancing the foam spray range of compressed air foam nozzle

open access: yesJournal of Safety Science and Resilience
As the core equipment in power systems, ultra-high voltage (UHV) transformers pose a high fire risk. The compressed-air foam spray nozzle is a novel end-release device that, due to its high efficiency and excellent suppression effect on oil-based fires ...
Fengju Shang   +6 more
doaj   +1 more source

Asset Management of Power Transformer Protective Devices in Transmission System

open access: yesThe Proceedings of the 4th International Conference on Industrial Application Engineering 2016, 2016
Las empresas eléctricas enfrentan altos riesgos en los costos de adquisición y mantenimiento de sus activos e intentan lograr la máxima utilización de sus activos existentes durante el ciclo de vida. La gestión de activos, especialmente el mantenimiento centrado en la fiabilidad, se utiliza para reducir el riesgo de mantenimiento.
Rattanakorn Phadungthin, Juthathip Haema
openaire   +2 more sources

Influence of an Argon/Silane Atmosphere on the Temperature of a Thermal Plasma

open access: yesAdvanced Engineering Materials, EarlyView.
The influence of a silane‐doped argon atmosphere on the chemical composition and temperature of a thermal nontransferring argon plasma is investigated using optical emission spectroscopy. As a result of the high amount of free electrons resulting from the stepwise ionization and dissociation of the silane molecule, even a silane addition of 0.01 vol ...
Lena Kreie   +4 more
wiley   +1 more source

Effect of oil immersion on the horizontal flame spread over transformer insulating paperboard with different sizes

open access: yesCase Studies in Thermal Engineering
Transformer oil and insulating paperboard are widely used in oil-immersed transformers and may be ignited in the event of device failure. The present study aims to investigate the effect of oil immersion on the horizontal flame spread over the ...
Yubiao Huang   +3 more
doaj   +1 more source

Проектирование релейной защиты линии электропередач 220 кВ ПС «Краснополянская » – Беловская ГРЭС Кузбасской ЭЭС [PDF]

open access: yes, 2016
-Объектом исследования являются релейная защита и автоматика линии 220 кВ. Цель работы – Проектирование релейной защиты линии электропередач 220 кВ ПС «Краснополянская » – Беловская ГРЭС Кузбасской ЭЭС В процессе исследования проводились ...
Нусратиллаев, Илхомжон Алишер угли
core  

Electrical Conductivities of Conductors, Semiconductors, and Their Mixtures at Elevated Temperatures

open access: yesAdvanced Engineering Materials, EarlyView.
This article presents a comprehensive review of temperature‐dependent electrical conductivity data for multiple material classes at elevated temperatures, highlighting a persistent conductivity gap between metals and semiconductors in the range of 102$\left(10\right)^{2}$– 107$\left(10\right)^{7}$ S/m. Metal–ceramic irregular metamaterials are proposed
Valentina Torres Nieto, Marcia A. Cooper
wiley   +1 more source

Structure optimal design of 500 kV dry-type air-core shunt reactor based on response surface method

open access: yesAIP Advances
The hotspot temperature of the reactor is one of the important indices in reactor design, and the appropriate hotspot value can ensure that the reactor will not overheat failure and threaten the safety of the power system.
Yanjing Zhu   +6 more
doaj   +1 more source