Results 11 to 20 of about 34,277 (159)

Titanium Coated with Graphene and Niobium Pentoxide for Biomaterial Applications

open access: yesInternational Journal of Biomaterials, Volume 2022, Issue 1, 2022., 2022
Graphene and niobium oxide are used in biomaterial coatings. In this work, commercially pure titanium (cp Ti) was coated with graphene oxide (GO), niobium pentoxide (Nb2O5), and a mixture of both materials (NbGO) by the electrochemical deposition method. The surface morphology, roughness, wettability, and degradation of coated and uncoated samples were
Hazel Paloma Reis Corado   +5 more
wiley   +1 more source

Galvanic Corrosion of Ti Dental Implants Coupled to CoCrMo Prosthetic Component

open access: yesInternational Journal of Biomaterials, Volume 2021, Issue 1, 2021., 2021
Dental implant systems are composed of an implant, prosthetic components, and a crown. Since the implants are made of commercially pure Ti (cp Ti) and prosthetic components are often made of Ti and CoCrMo alloys, a galvanic couple between these two devices may lead to galvanic corrosion, ions release, and even loss of the implant.
Francielly M. S. Soares   +5 more
wiley   +1 more source

A Prosthetic and Surgical Approach for Full‐Arch Rehabilitation in Atrophic Maxilla Previously Affected by Peri‐Implantitis

open access: yesCase Reports in Dentistry, Volume 2021, Issue 1, 2021., 2021
Rehabilitation of atrophic maxilla with dental implants is still a challenge in clinical practice especially in cases of alveolar bone resorption due to peri‐implantitis and pneumatization of the maxillary sinuses. Several surgical approaches have been employed to reconstruct the lost tissues allowing the proper tridimensional position of the implants.
Angélica Letícia Reis Pavanelli   +7 more
wiley   +1 more source

In Vitro Toxic Effect of Biomaterials Coated with Silver Tungstate or Silver Molybdate Microcrystals

open access: yesJournal of Nanomaterials, Volume 2020, Issue 1, 2020., 2020
Purpose. This study evaluated the cytotoxicity of antimicrobial silver tungstate (Ag2WO4) or silver molybdate (Ag2MoO4) microcrystals coating biomaterials. Materials and Methods. The coating procedure was performed onto titanium, zirconia, and acrylic resin specimens.
Claudia Viviane Guimarães Pellissari   +7 more
wiley   +1 more source

Adesividade de zircônia e dissilicato de lítio após diferentes tratamentos de superfície: revisão de literatura

open access: yesRevista Brasileira de Odontologia, 2018
Objetivo: este estudo tem como objetivo avaliar, através de uma revisão da literatura, a adesividade da zircônia e do dissilicato de lítio após diferentes tratamentos de superfície e estabelecer um protocolo a ser seguido na clínica.
Renata Ventura Azevedo Lopes   +4 more
doaj   +1 more source

Prótese intra-ocular de resina acrílica em cães e gatos Acrylic resin intraocular prosthesis in dogs and cats

open access: yesArquivo Brasileiro de Medicina Veterinária e Zootecnia, 2000
Foram atendidos no Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Unesp - Campus de Botucatu, 11 animais (oito cães e três gatos), com alterações oftálmicas unilaterais graves que levaram à perda total da função ocular ...
S.C. Rahal, F.M.M. Bergamo, H.M. Ishiy
doaj   +1 more source

Alterações miofuncionais em adultos e idosos usuários de prótese dentária

open access: yesRevista da Faculdade de Odontologia de Porto Alegre, 2012
Objetivo: Descrever os aspectos miofuncionais orais dos indivíduos adultos e idosos usuários de próteses dentárias. Materiais e métodos: Os sujeitos foram divididos em seis grupos de acordo com o tipo de prótese dentária.
Annelise Ayres   +7 more
doaj   +9 more sources

Reabilitação protética bucomaxilofacial: revisão de literatura e relato de caso

open access: yesRevista da Faculdade de Odontologia de Porto Alegre, 2018
O presente trabalho visou relatar um caso clínico de deformidade facial de etiologia traumática, reabilitado através de prótese óculo-palpebral no Programa de Extensão em Prótese Bucomaxilofacial da Faculdade de Odontologia da UFRGS.
Samira Carvalho   +2 more
doaj   +1 more source

Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three‐Dimensional Finite Element Analysis

open access: yesJournal of Healthcare Engineering, Volume 2018, Issue 1, 2018., 2018
The aim of this study was to evaluate stress distribution in the implants/components and bone tissue for splinted and nonsplinted prostheses with different lengths of implants using three‐dimensional finite element analysis. Six models from the posterior maxillary area were used in simulations.
Cleidiel Aparecido Araujo Lemos   +7 more
wiley   +1 more source

Periodontics, Implantology, and Prosthodontics Integrated: The Zenith‐Driven Rehabilitation

open access: yesCase Reports in Dentistry, Volume 2017, Issue 1, 2017., 2017
A customized treatment plan is important to reach results that will satisfy the patient providing esthetics, function, and long‐term stability. This type of oral rehabilitation requires professionals from different dental specialties where communication is a major key point.
Fausto Frizzera   +5 more
wiley   +1 more source