Results 111 to 120 of about 9,532 (254)

All‐in‐One Analog AI Hardware: On‐Chip Training and Inference with Conductive‐Metal‐Oxide/HfOx ReRAM Devices

open access: yesAdvanced Functional Materials, EarlyView.
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone   +11 more
wiley   +1 more source

Laser‐Induced Graphene from Waste Almond Shells

open access: yesAdvanced Functional Materials, EarlyView.
Almond shells, an abundant agricultural by‐product, are repurposed to create a fully bioderived almond shell/chitosan composite (ASC) degradable in soil. ASC is converted into laser‐induced graphene (LIG) by laser scribing and proposed as a substrate for transient electronics.
Yulia Steksova   +9 more
wiley   +1 more source

Strain‐Programmable Luminescent Adhesive Patch With Tartrazine‐Mediated Optical Skin Clearing for Photochemical Tissue Bonding

open access: yesAdvanced Functional Materials, EarlyView.
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim   +6 more
wiley   +1 more source

Oxygen‐Tunnel Indium Tin Oxide Vertical Channel Transistors with Enhanced Current Density and Reliability for Monolithic 3D Compute‐In‐Memory Systems

open access: yesAdvanced Functional Materials, EarlyView.
Oxygen‐tunnel (OT) indium tin oxide (ITO) vertical channel transistors (VCTs) enable reliable, high‐density gain‐cell memory for monolithic 3D integration. A sandwiched SiN/SiO2/SiN OT stack selectively regulates oxygen transport, suppressing parasitic electrode oxidation while stabilizing channel oxygen vacancies, thereby suppressing carrier injection
Hyeonho Gu   +17 more
wiley   +1 more source

Chemical State Detection and Charge Transfer in Complex Oxide Heterostructures via In Situ Auger Electron Spectroscopy

open access: yesAdvanced Functional Materials, EarlyView.
In situ Auger Electron Spectroscopy resolves oxidation states with high fidelity during the pulsed laser deposition of multivalent perovskite manganate and vanadate heterostructures. The chemical‐state signature is carried by the valence‐electron population of the transition‐metal cation, read out through the relative intensities of Auger fine ...
Harish Kumarasubramanian   +1 more
wiley   +1 more source

Three‐Dimensional Anomalous Hall Sensing Enabled By Spin–Orbit Torque Driven Domain Reconfiguration In Chiral Multilayers

open access: yesAdvanced Functional Materials, EarlyView.
A three‐dimensional magnetic field sensor is realized in chiral W/CoFeB/MgO multilayers, where spin–orbit torques reversibly reconfigure homochiral stripe domains. The symmetry of the torque enables offset‐free in‐plane sensing, while the reproducible domain reconfiguration extends the linear out‐of‐plane range. An anomalous Hall readout delivers large‐
Sabri Koraltan   +16 more
wiley   +1 more source

Electrode and Microstructure Dependence of Oxygen Diffusion in Ferroelectric Hafnium Zirconium Oxide Thin Films

open access: yesAdvanced Functional Materials, EarlyView.
Significant nanoscale oxygen diffusion coefficient variations are measured in ferroelectric hafnium zirconium oxide films with grain boundaries and electrode interfaces exhibiting values 104 times larger than the grain cores. Overall coefficients are 10X larger for films prepared with metal nitride electrodes compared to refractory metals. New insights
Liron Shvilberg   +6 more
wiley   +1 more source

Historical Foundation and Practical Guideline for Ferroelectric Switching Kinetic Studies

open access: yesAdvanced Functional Materials, EarlyView.
The P and U pulses in the conventional PUND measurements are not identical because of the interplay between switching current and the measurement circuit components. This circuit effect can lead to a shift in polarization transients and misinterpreted physics in the switching kinetics.
Yi Liang, Pat Kezer, John T. Heron
wiley   +1 more source

Home - About - Disclaimer - Privacy