Results 131 to 140 of about 2,311,006 (294)

Real‐Time In Vivo Monitoring of Anastomotic Intestinal Ischemia Using Implantable Resorbable Organic Sensors

open access: yesAdvanced Science, EarlyView.
Resorbable impedance sensors are successfully implanted into porcine small intestinal anastomoses. Impedance was recorded for 2 hours prior, and 2 hours following ischemia induction, and a significant drop in tissue impedance was observed. Abstract Anastomotic failure remains one of the most severe complications in gastrointestinal surgery.
Dennis Wahl   +12 more
wiley   +1 more source

Systematic Benchmarking of a Noise‐Tolerant Conductive Hydrogel Electrode for Epidermal Bioelectronics

open access: yesAdvanced Science, EarlyView.
General schematic of the approach. Abstract Conventional Silver/Silver Chloride (Ag/AgCl) electrodes remain the clinical standard for electrophysiological monitoring but are hindered by poor skin conformity, mechanical rigidity, and signal degradation, particularly under motion or sweat.
Nazmi Alsaafeen   +11 more
wiley   +1 more source

Targeting the GPX4–FUNDC1 Interaction with Magnesium Lithospermate B Attenuates Sepsis‐Associated Lung Injury

open access: yesAdvanced Science, EarlyView.
The diagram depicts the endothelial‐protective mechanism of magnesium lithospermate B (MLB) in sepsis‐associated lung injury. MLB binds GPX4 at Gly79, disrupts its interaction with FUNDC1, prevents mitophagy‐mediated GPX4 degradation, restores mitophagic flux, reduces ROS, and limits ferroptosis.
Zhixi Li   +10 more
wiley   +1 more source

Oncolytic Probiotics with Molecular Pili for Solid Tumor Therapy

open access: yesAdvanced Science, EarlyView.
This study identifies Lactobacillus rhamnosus as an intrinsic oncolytic agent that triggers tumor metabolic collapse via calcium‐dependent ROS bursts. By chemically anchoring collagen‐targeting “molecular pili” to the bacterial surface, the engineered non‐transgenic probiotic (LR@MP) achieves targeted colonization and potent solid tumor suppression ...
Haodong Ge   +14 more
wiley   +1 more source

Origins of Graphite Resistivity: Decoupling Stacking Fault and Rotational Misorientation

open access: yesAdvanced Science, EarlyView.
Interfacial dislocations critically influence interlayer transport in van der Waals (vdW) materials, yet quantifying their individual contributions remains challenging. We measure graphite's c‐axis resistivity and develop a decoupling strategy, revealing a resistivity ratio of ∼4507:74:1 for rotational misorientations, stacking faults, and AB stacking,
Weipeng Chen   +6 more
wiley   +1 more source

Mango Fructokinases Inhibit Sugar Accumulation and Enhance Energy Metabolism in Transgenic Tomato

open access: yesPlants
Sugar content critically determines mango fruit quality and varies significantly among varieties. Preliminary studies indicate that fructokinases (MiFRKs) MiFRK1 and MiFRK2 likely regulate intervarietal sugar variation.
Bin Zheng   +10 more
doaj   +1 more source

Hierarchical Strain‐Modified Medium‐Entropy Carbide Ceramics Exhibit Exceptional Ablation Resistance up to 2400°C

open access: yesAdvanced Science, EarlyView.
A novel strategy is developed by doping reduced graphene oxide (rGO) into a (HfZrTi)C medium‐entropy ceramic. This induces a hierarchical strain modification mechanism, synergistically inhibiting crack propagation at the microscale and dissipating stress at the mesoscale.
Junyi Xiao   +8 more
wiley   +1 more source

Feasibility of an Incoherent-scatter Radar Aboard the Space Shuttle [PDF]

open access: yes
The results of a preliminary study to investigate the feasibility of conducting an incoherent scatter radar experiment on board the space shuttle are presented. The results indicate that such an experiment is technically feasible.
Baron, M. J.   +3 more
core   +1 more source

Understanding the Roles of Microstructure and Viscoelasticity of Soft Ionic Elastomer for Super‐Capacitive Pressure Sensors

open access: yesAdvanced Science, EarlyView.
By engineering the PVA/H3PO4 ionic elastomer with optimized viscoelasticity and a height‐graded microstructure, the pressure sensor achieves a broad linear range up to 2000 kPa and a high sensitivity of 2.70 nF/kPa. These advancements underscore its strong potential for wearable electronics, including bio‐signal detection, health monitoring, and ...
Allen J. Cheng   +13 more
wiley   +1 more source

Atomically Precise Clusterzymes: A Programmable Optoelectronic Platform for Neuroscience

open access: yesAdvanced Science, EarlyView.
Atomically precise clusterzymes, engineered via atomic and ligand design, serve as programmable platforms for neuroscience applications. They demonstrate tailored biocatalysis for neuroinflammation, tunable optical properties for deep‐tissue bioimaging and 3D visualization, and enhanced charge transfer for brain–computer interfaces.
Si Sun   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy