Results 111 to 120 of about 6,724,534 (242)
Log file‐based quality assurance method for respiratory gating system
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon+7 more
wiley +1 more source
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin+5 more
wiley +1 more source
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley+4 more
wiley +1 more source
[Expert consensus on the whole-process management model of lymphoma patients in China (2021)]. [PDF]
Union for China Lymphoma Invesingators+2 more
europepmc +1 more source
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa+4 more
wiley +1 more source
Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda+9 more
wiley +1 more source
[Whole-process Management of Treatment of Advanced ALK Positive Non-small Cell Lung Cancer: A Case Report]. [PDF]
Bai H, Han Y, Niu Y, Zhang M.
europepmc +1 more source
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley +1 more source
Process management method in head and neck cancer patient care. [PDF]
De Felice F+22 more
europepmc +1 more source