Results 61 to 70 of about 2,359,967 (297)
Abstract Purpose The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. Methods Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross
Abram Abdou+4 more
wiley +1 more source
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi+3 more
wiley +1 more source
Abstract Background Dual‐energy cone‐beam CT (DE‐CBCT) has become subject of recent interest due to the ability to produce virtual monoenergetic images (VMIs) with improved soft‐tissue contrast and reduced nonuniformity artifacts. However, efficient production and optimization of VMIs remains an under‐explored part of DE‐CBCT's application.
Andrew Keeler+4 more
wiley +1 more source
Renewal reward processes with heavy-tailed inter-renewal times and heavy-tailed rewards
It is well known that fractional Brownian motion can be obtained as the limit of a superposition of renewal reward processes with inter-renewal times that have infinite variance (heavy tails with exponent a) and with rewards that have finite variance. We
J. Levy, M. Taqqu
semanticscholar +1 more source
A Python package for fast GPU‐based proton pencil beam dose calculation
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya+4 more
wiley +1 more source
Machine stability and dosimetry for ultra‐high dose rate FLASH radiotherapy human clinical protocol
Abstract Background The FLASH effect, induced by ultra‐high dose rate (UHDR) irradiations, offers the potential to spare normal tissue while effectively treating tumors. It is important to achieve precise and accurate dose delivery and to establish reliable detector systems, particularly for clinical trials needed to help the clinical transfer of FLASH‐
Patrik Gonçalves Jorge+9 more
wiley +1 more source
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen+3 more
wiley +1 more source
Abstract Objective Exploring the prevalence and association between intracranial atherosclerosis (ICAS) and cerebral small vessel diseases (CSVD), this study delved beyond the current scope, utilising high‐resolution vessel wall MRI (HRVW‐MRI) to investigate how subtle changes in intracranial atherosclerotic features influence the various burdens of ...
Joseph Amihere Ackah+6 more
wiley +1 more source
Incremental Variational Inference for Latent Dirichlet Allocation [PDF]
We introduce incremental variational inference and apply it to latent Dirichlet allocation (LDA). Incremental variational inference is inspired by incremental EM and provides an alternative to stochastic variational inference. Incremental LDA can process massive document collections, does not require to set a learning rate, converges faster to a local ...
arxiv
TAPIR: Learning Adaptive Revision for Incremental Natural Language Understanding with a Two-Pass Model [PDF]
Language is by its very nature incremental in how it is produced and processed. This property can be exploited by NLP systems to produce fast responses, which has been shown to be beneficial for real-time interactive applications. Recent neural network-based approaches for incremental processing mainly use RNNs or Transformers.
arxiv