Results 61 to 70 of about 28,914 (258)

Features of Metalorganic Chemical Vapor Deposition Selective Area Epitaxy of AlzGa1−zAs (0 ≤ z ≤ 0.3) Layers in Arrays of Ultrawide Windows

open access: yesTechnologies, 2023
AlzGa1−zAs layers of various compositions were grown using metalorganic chemical vapor deposition on a GaAs substrate with a pattern of alternating SiO2 mask/window stripes, each 100 µm wide.
Viktor Shamakhov   +10 more
doaj   +1 more source

Unraveling Quantitative Sensing Mechanism and Predictive Molecular Metrics for High‐Performance OFET Amine Sensors

open access: yesAdvanced Functional Materials, EarlyView.
This study introduces a novel chloro boron subphthalocyanine/polymer blend OFET sensor achieving 0.005 ppb limit of detection for ammonia at room temperature and high selectivity against similar amines. An original theoretical framework is proposed to describe the sensing mechanism, relating analyte molecular volume and Lewis basicity to sensor ...
Kavinraaj Ella Elangovan   +6 more
wiley   +1 more source

Toothpaste Abrasion and Abrasive Particle Content: Correlating High-Resolution Profilometric Analysis with Relative Dentin Abrasivity (RDA)

open access: yesDentistry Journal, 2023
In this in vitro study, the influence of the concentration of abrasive particles on the abrasivity of toothpastes was investigated using laser scan profilometry on polymethyl methacrylate (PMMA) surfaces with the aim of providing an alternative method to
Joachim Enax   +4 more
doaj   +1 more source

Transition from Weak Wave Turbulence to Soliton-Gas

open access: yes, 2017
We report an experimental investigation of the effect of finite depth on the statistical properties of wave turbulence at the surface of water in the gravity-capillary range.
Hassaini, Roumaissa, Mordant, Nicolas
core   +3 more sources

Characterization of ISF-VAT performance in weak magnetic nozzle

open access: yes, 2020
Vacuum arc thruster performance in a magnetic nozzle configuration is experimentally characterized. Measurements are performed on a miniature coaxial thruster with an anode inner diameter of $1.8$ mm. The magnetic field B is produced by a single air coil,
Chowdhury, Satyajit, Kronhaus, Igal
core   +1 more source

Effective Penetration of the Oxidized Keratin‐Rebonding Materials Into Hair Shafts Based on Charge Conversion

open access: yesAdvanced Healthcare Materials, EarlyView.
We have developed a smart hair‐repair ingredient based on β‐carboxylic acid amide that undergoes negative‐to‐positive charge conversion under mildly acidic conditions. The initial negative charge facilitates deep penetration into the hair fiber, while the subsequent positive charge enables re‐bonding with sulfonate groups in damaged hair keratin.
Sunyoung Kang   +8 more
wiley   +1 more source

The Influence of the Relative Sliding on the Surface Quality [PDF]

open access: yesTribology in Industry, 2011
This paper presents a study on the surface quality pointing out the influence of relative sliding on the topography parameters. Traditional roughness parameters as Ra and Rq, deal only with relative high of the asperities to the mean line and they give ...
N. Diaconu   +3 more
doaj  

In Vivo Skin 3‐D Surface Reconstruction and Wrinkle Depth Estimation Using Handheld High Resolution Tactile Sensing

open access: yesAdvanced Healthcare Materials, EarlyView.
A compact handheld GelSight probe reconstructs in vivo 3‐D skin topography with micron‐level precision using a custom elastic gel and a learning‐based surface normal to height map pipeline. The device quantifies wrinkle depth across various body locations and detects changes in wrinkle depth following moisturizer application.
Akhil Padmanabha   +12 more
wiley   +1 more source

Flexible Polypyrrole‐Based pH Sensors via Oxidative Chemical Vapor Deposition

open access: yesAdvanced Healthcare Materials, EarlyView.
Oxidative chemical vapor deposition (oCVD) of polypyrrole (PPy) thin films yields flexible, electrically conductive, and biocompatible pH sensors for monitoring on‐skin biological events. The highly sensitive, oCVD PPy skin‐conformal sensors enable real‐time, spatially resolved sensing of dynamic pH changes within physiologically relevant ranges (4–9 ...
Adrivit Mukherjee   +15 more
wiley   +1 more source

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

open access: yesJournal of Synchrotron Radiation
Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a ...
Ralf D. Geckeler   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy