Results 191 to 200 of about 8,686,058 (373)

Characterization of a prototype rapid kilovoltage x‐ray image guidance system designed for a linear accelerator radiation therapy unit

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault   +9 more
wiley   +1 more source

The topology of spaces of holomorphic maps to projective space [PDF]

open access: yesarXiv
We show that the spaces of holomorphic and continuous maps from a smooth complex projective variety to a projective space have the same homology in a range depending on the degree of the maps.
arxiv  

Effects of simultaneous multislice acceleration on the stability of radiomics features in parametric maps of IVIM and DKI in uterine cervical cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The aim of this study was to investigate the influence of the simultaneous multislice acceleration (SMS) technique as well as two‐dimensional (2D) and three‐dimensional (3D) tumor segmentations on radiomics features (RFs) within the parametric maps of cervical cancer, which were computed by intravoxel incoherent motion (IVIM) and ...
Shuangquan Ai   +6 more
wiley   +1 more source

Practical experience in commissioning ring applicators using ring applicator component type with bravos control software v1.2

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The Bravos v1.2 control software introduces a ring applicator component type (ACT) with channel length verification to address geometric characteristics and dosimetric discrepancies caused by source positioning inaccuracies. This study aims to commission the ring applicator and investigate the new ring ACT in Bravos 1.2.
Xiuxiu He   +4 more
wiley   +1 more source

Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single‐isocenter VMAT: Normal brain dose based on lesion number and size

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. Methods Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross
Abram Abdou   +4 more
wiley   +1 more source

Projective embedding of projective spaces [PDF]

open access: yesBulletin of the Belgian Mathematical Society - Simon Stevin, 1998
openaire   +2 more sources

Geometric and dosimetric evaluation of a commercial AI auto‐contouring tool on multiple anatomical sites in CT scans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy