Results 1 to 10 of about 1,627,153 (385)

Novel concept for neutron detection: proportional counter filled with 10B nanoparticle aerosol. [PDF]

open access: yesSci Rep, 2017
The high neutron detection efficiency, good gamma-ray discrimination and non-toxicity of 3He made of proportional counters filled with this gas the obvious choice for neutron detection, particularly in radiation portal monitors (RPM), used to control the
Amaro FD   +3 more
europepmc   +2 more sources

Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions. [PDF]

open access: yesHealth Phys, 2015
Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time.
Straume T   +5 more
europepmc   +2 more sources

Low energy recoil detection with a spherical proportional counter [PDF]

open access: yes, 2017
We present low energy recoil detection results in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC).
Eleftheriadis, C.   +4 more
core   +5 more sources

A Novel Hybrid Microdosimeter for Radiation Field Characterization Based on the Tissue Equivalent Proportional Counter Detector and Low Gain Avalanche Detectors Tracker: A Feasibility Study

open access: yesFrontiers in Physics, 2021
In microdosimetry, lineal energies y are calculated from energy depositions ϵ inside the microdosimeter divided by the mean chord length, whose value is based on geometrical assumptions on both the detector and the radiation field.
M. Missiaggia   +22 more
doaj   +2 more sources

Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station [PDF]

open access: goldJournal of Astronomy and Space Sciences, 2013
Tissue equivalent proportional counter (TEPC) can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in space.
Uk-Won Nam   +9 more
doaj   +3 more sources

Comparison of ZnS(Ag) Scintillator and Proportional Counter Tube for Alpha Detection in Thin-Layer Chromatography [PDF]

open access: yesPharmaceuticals
(1) Background: Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of 212Pb- and 225Ac-labelled ...
Marc Pretze   +6 more
doaj   +2 more sources

PROPORTIONAL COUNTER PHOTON CAMERA. [PDF]

open access: goldIEEE Transactions on Nuclear Science, 1972
A gas-filled proportional counter camera that images photon emitting sources was built and tested. This camera measures and displays the impact location of individual photons in an energy range between 1 and 150 keV and permits pulse shape and energy discrimination for background reduction.
Borkowski, C. J., Kopp, M. K.
  +5 more sources

Neutron spectroscopy with the Spherical Proportional Counter

open access: yes, 2017
A novel large volume spherical proportional counter, recently developed, is used for neutron measurements. Gas mixtures of $N_{2}$ with $C_{2}H_{6}$ and pure $N_{2}$ are studied for thermal and fast neutron detection, providing a new way for the neutron ...
Bougamont, E.   +13 more
core   +4 more sources

Quality control of actinium-225 and 225Ac-radiopharmaceuticals: Francium-221 to be or not to be? [PDF]

open access: yesEJNMMI Radiopharmacy and Chemistry
Background Actinium-225 radiopharmaceuticals have drawn great interest in cancer therapy due to their tumor-specific delivery of cytotoxic alpha-particles.
Miguel Toro-Gonzalez   +10 more
doaj   +2 more sources

Advances in the RXTE Proportional Counter Array Calibration: Nearing the Statistical Limit [PDF]

open access: yes, 2012
During its 16 years of service the Rossi X-ray Timing Explorer (RXTE) mission has provided an extensive archive of data, which will serve as a primary source of high cadence observations of variable X-ray sources for fast timing studies. It is, therefore,
Arnaud   +11 more
core   +5 more sources

Home - About - Disclaimer - Privacy