Results 11 to 20 of about 1,577,460 (391)
Fine Powder Proportional Counters for Neutron Detection
A novel neutron detection approach is presented, consisting of a neutron sensitive aerosol obtained by dispersing B4C fine powder in a gaseous proportional counter operating in continuous flow, which proved to effectively detect thermal neutrons.
Nuno Duarte+2 more
doaj +1 more source
In the absolute measurement method of nuclide radioactivity by the internal gas proportional counter, the reasonable correction of the small pulse counting loss is the key to accurately obtain the measurement results.
KONG Shuying1;ZHANG Ming2,*;WANG Rensheng3;TUO Fei1
doaj +1 more source
Development of a multiwire position sensitive proportional counter [PDF]
Preliminary measurements in a proportional counter with two independently counting wires have shown that counting rates up to 106 counts/s per wire can be reached without critical loss in the “true versus measured” linearity relation. In this paper, a
Kakavand Tayeb+3 more
doaj +1 more source
Determination of Sr-90 in milk samples from the study of statistical results [PDF]
The determination of 90Sr in milk samples is the main objective of radiation monitoring laboratories because of its environmental importance. In this paper the concentration of activity of 39 milk samples was obtained through radiochemical ...
Otero-Pazos Alberto+5 more
doaj +1 more source
Liquid-Filled Proportional Counter [PDF]
We report properties of single-wire proportional chambers and multiple-wire ionization chambers filled with liquid xenon. Proportional multiplication is seen for anode fields > 10{sup 6} volts/cm (anode-cathode voltage> 1 kV for a 3.5-{micro}-diam anode wire). The efficiency for detecting ionizing radiation is {approx} 100%.
Muller, Richard A.+6 more
openaire +5 more sources
APPLICATION OF CALCULATED MSM FACTORS USING TRIPOLI4® SEQUENCE ON BORON LINED PROPORTIONAL COUNTER ROD WORTH MEASUREMENT [PDF]
The topic addressed deals with the determination of adjoint parameters for instrumentation relevance. This is a crucial subject for comprehension of subcritical levels in the frame of safety analysis.
Couybes J.+5 more
doaj +1 more source
A sparkless resistive glass correction electrode for the spherical proportional counter [PDF]
A new anode support structure for the spherical proportional counter is presented that incorporates a resistive correction electrode made of glass. This electrode improves the electric field homogeneity versus angle, while suppressing the probability and
I. Katsioulas+6 more
semanticscholar +1 more source
Calibration of the Large Area X-Ray Proportional Counter (LAXPC) Instrument on board AstroSat [PDF]
We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on board AstroSat. The LAXPC instrument has three nominally identical detectors to achieve a large collecting area.
H. M. Antia+23 more
semanticscholar +1 more source
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
The tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement.
Min Zhu+7 more
doaj +1 more source
Status and future prospects of the NEWS-G experiment
The NEWS-G collaboration is searching for light dark matter using spherical proportional counters. Access to the mass range from 50 MeV to 10 GeV is enabled by the combination of low energy threshold, light gaseous targets (H, He, Ne), and highly radio ...
P. Knights on behalf of the NEWS-G Collaboration
doaj +1 more source