Calibration of the Large Area X-Ray Proportional Counter (LAXPC) Instrument on board AstroSat [PDF]
We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on board AstroSat. The LAXPC instrument has three nominally identical detectors to achieve a large collecting area.
H. M. Antia +23 more
semanticscholar +1 more source
A multiball read-out for the spherical proportional counter [PDF]
We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high-pressure operations.
A. Giganon +8 more
semanticscholar +1 more source
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
The tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement.
Min Zhu +7 more
doaj +1 more source
Liquid-Filled Proportional Counter [PDF]
We report properties of single-wire proportional chambers and multiple-wire ionization chambers filled with liquid xenon. Proportional multiplication is seen for anode fields > 10{sup 6} volts/cm (anode-cathode voltage> 1 kV for a 3.5-{micro}-diam anode wire). The efficiency for detecting ionizing radiation is {approx} 100%.
Muller, Richard A. +6 more
openaire +4 more sources
Large Area X-Ray Proportional Counter (LAXPC) Instrument on AstroSat and Some Preliminary Results from its Performance in the Orbit [PDF]
Large area X-ray propositional counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3–80 keV energy band with moderate energy resolution.
P. Agrawal +27 more
semanticscholar +1 more source
Status and future prospects of the NEWS-G experiment
The NEWS-G collaboration is searching for light dark matter using spherical proportional counters. Access to the mass range from 50 MeV to 10 GeV is enabled by the combination of low energy threshold, light gaseous targets (H, He, Ne), and highly radio ...
P. Knights on behalf of the NEWS-G Collaboration
doaj +1 more source
Toward neutron / gamma discrimination with proportional counter using artificial intelligence [PDF]
Extending the neutron detection capabilities of the ROSPEC SP2-1 proportional counter below 50 keV requires effective discrimination between neutron and gamma-ray signals at low energies.
Kanj Aya, Babut Richard, Roux Louis
doaj +1 more source
Miniaturized tissue equivalent proportional counters (mini-TEPCs) are proper for radiation dosimetry in medical application because the small size of the dosimeter could prevent pile-up effect under the high intensity of therapeutic beam.
Mingi Eom, Sukwon Youn, Sung-Joon Ye
doaj +1 more source
Diseño e implementación de un detector de electrones en espectroscopia Mössbauer por reflexión
Se construyó un detector proporcional de flujo de gas para detectar electrones de la superficie de muestras en volumen y películas delgadas utilizando la técnica de Espectroscopia Mössbauer de electrones de conversión (CEMS).
Beatriz Cruz Muñoz +3 more
doaj +1 more source
A survey of hard spectrum ROSAT sources - II. Optical identification of hard sources [PDF]
We have surveyed 188 ROSAT Position Sensitive Proportional Counter (PSPC) fields for X-ray sources with hard spectra (alpha 1) identified hard sources have broad ...
Carrera, FJ, Mittaz, JPD, Page, MJ
core +1 more source