Results 51 to 60 of about 93,112 (390)

Fracture of abutment screw supporting a cemented implant-retained prosthesis with external hexagon connection: a case report with sem evaluation

open access: yesJournal of Applied Oral Science, 2007
One of the causes of implant failures in cemented implant-retained prostheses is the fracture of abutment screw or UCLA abutment. This article reports a case of simultaneous fracture of two UCLA abutments screws occurring in an implant-supported ...
Mariana Diniz Bisi Santos   +4 more
doaj   +1 more source

Mean Bone Density in Interadicular Areas of Maxilla among Patients Visiting Dental Unit of a Tertiary Care Centre: A Descriptive Cross-sectional Study

open access: yesJournal of Nepal Medical Association, 2023
Introduction: A close relationship occurs between the type of bone density and the success of orthodontic mini-implant. The aim of this study was to find out the mean bone density in interradicular areas of the maxilla among patients visiting dental ...
Hemant Kumar Halwai   +6 more
doaj   +1 more source

Osseointegrated finger prostheses using a tripod titanium mini-plate [PDF]

open access: yes, 2017
BACKGROUND: Digital amputation is a common upper extremity injury and can cause significant impairment in hand function, as well as psychosocial stigma.
Ciudad, Pedro   +5 more
core   +2 more sources

Development and Preliminary In Vivo Study of 3D‐Printed Bioactive Glass Scaffolds with Trabecular Architecture

open access: yesAdvanced Engineering Materials, EarlyView.
This study reports the fabrication of trabecular bioactive glass scaffolds (composition “1d”: 46.1SiO2‐28.7CaO‐8.8MgO‐6.2P2O5‐5.7CaF2‐4.5Na2O wt%) through vat photopolymerization and the relevant results from mechanical testing and in vivo implantation procedures in rabbit femora, showing great promise for bone tissue engineering applications.
Dilshat Tulyaganov   +8 more
wiley   +1 more source

Explant Analysis of Total Disc Replacement [PDF]

open access: yes, 2006
Explant analysis of human disc prostheses allow early evaluation of the host response to the prosthesis and the response of the prosthesis from the host. Furthermore, early predictions of failure and wear can be obtained.
Anderson, Paul A.   +2 more
core   +1 more source

Precaution, governance and the failure of medical implants: the ASR(TM) hip in the UK [PDF]

open access: yes, 2014
Hip implants have provided life-changing treatment, reducing pain and improving the mobility and independence of patients. Success has encouraged manufacturers to innovate and amend designs, engendering patient hopes in these devices.
Joyce, Thomas   +2 more
core   +1 more source

Wearable Haptic Feedback Interfaces for Augmenting Human Touch

open access: yesAdvanced Functional Materials, EarlyView.
The wearable haptic feedback interfaces enhance user experience in gaming, social media, biomedical instrumentation, and robotics by generating tactile sensations. This review discusses and categorizes current haptic feedback interfaces into force, thermal, and electrotactile stimulation‐based haptic feedback interfaces, elucidating their current ...
Shubham Patel   +3 more
wiley   +1 more source

Assessment of survival rate of dental implants in patients with bruxism: A 5-year retrospective study

open access: yesContemporary Clinical Dentistry, 2018
Background: Dental implants are associated with failure such as early or late failure. Systemic conditions such as diabetes, hypertension, and bruxism affect the success rate.
Rajkiran Chitumalla   +5 more
doaj   +1 more source

Prosthetic Rehabilitation Following Lateral Resection of the Mandible with a Long Cantilever Implant-Supported Fixed Prosthesis: A 3-Year Clinical Report [PDF]

open access: yes, 2017
This clinical report describes the prosthetic management of the surgical reconstruction of a patient after mandibular resection. Complete oral rehabilitation was achieved with a maxillary complete denture and a mandibular implant-supported fixed ...
Ahmed, Ayman   +3 more
core   +1 more source

Micropatterned Biphasic Printed Electrodes for High‐Fidelity on‐Skin Bioelectronics

open access: yesAdvanced Functional Materials, EarlyView.
Micropatterned biphasic printed electrodes achieve unprecedented skin conformity and low impedance by combining liquid‐metal droplets with microstructured 3D lattices. This scalable approach enables high‐fidelity detection of ECG, EMG, and EEG signals, including alpha rhythms from the forehead, with long‐term comfort and stability.
Manuel Reis Carneiro   +4 more
wiley   +1 more source