Results 141 to 150 of about 206,749 (300)
Ultrathin, Fully Solution‐Processed P(VDF‐TrFE) Piezoelectric Sensor Matrix for Electronic Skin
An ultrathin, fully solution‐processed 4×$\times$4 piezoelectric sensor array is developed for skinconformal electronicskin applications. The device integrates inkjetprinted polymer electrodes with a 226 nm P(VDFTrFE) active layer on a 4.53 μm$\umu{\rm m}$ Parylene C substrate, enabling extreme flexibility and robust tactile sensing. The array exhibits
Ninja Kajas +4 more
wiley +1 more source
Supercritical Solution Impregnation: A Strategy to Prevent Prosthetic Infections. [PDF]
Salas A +7 more
europepmc +1 more source
Purpose The purpose of this study was to evaluate the influence of different types of bone on the stress distribution in the mandibular bone supporting a prefabricated bar type implant prosthesis using three dimensional finite element analysis Materials ...
Martin, Manoel +3 more
core
Flexible tactile sensors have considerable potential for broad application in healthcare monitoring, human–machine interfaces, and bioinspired robotics. This review explores recent progress in device design, performance optimization, and intelligent applications. It highlights how AI algorithms enhance environmental adaptability and perception accuracy
Siyuan Wang +3 more
wiley +1 more source
Does the material of the external ocular prosthesis matter? Clinical outcomes after enucleation with orbital implantation. [PDF]
Pociej-Marciak W +2 more
europepmc +1 more source
This article describes a multimodal fusion data acquisition and processing system about electromyography for dynamic movement recognition and bioelectrical impedance for key posture recognition. In addition, a new dynamic–static fusion algorithm strategy is designed.
Chenhao Cao +5 more
wiley +1 more source
3D-Printed Region-Specific Biomimetic Prosthesis for Enhancing Heterogeneous Double-Interface Integration of Bone-Prosthesis and Tendon-Prosthesis. [PDF]
Zhang J +7 more
europepmc +1 more source
We demonstrate the direct‐laser patterning of a gold thin film on polymethyl methacrylate to fabricate a temperature sensor for dentures. The temperature sensor‐embedded smart dentures are evaluated in an oral environment, enabling in‐situ monitoring for elderly healthcare.
Han Ku Nam +7 more
wiley +1 more source
The ArchBridge™ Digitally Integrated Workflow: A Fully Digital, Model-Free Workflow for Implant-Supported Overdenture Rehabilitation. [PDF]
Jernigan J, Kurtzman GM.
europepmc +1 more source