Comparison of Intraoperative Doppler Flow Measurements and Algorithmic Flow Estimations in Patients Undergoing Durable Left Ventricular Assist Device Implantation

open access: yesArtificial Organs, EarlyView.
Direct intraoperative HeartMate 3 LVAD flow measurements using an ultrasonic probe revealed consistently higher values by approximately 0.5 L/min compared to device‐estimated flows. This discrepancy remained stable across pump speed settings, highlighting the importance of distinguishing measured from estimated flow in HeartMate 3 patients.
Gaik Nersesian   +13 more
wiley   +1 more source

Effect of prosthesis manufacturing techniques on color and roughness

open access: yesInternational Dental Journal
Sinem Uzun, Aysegul Kurt, Hanefi Kurt
openaire   +1 more source

Identification of Autologous Tissue Sources and Optimization of a Treatment Method for Intraoperative Manufacturing of Heart Valve Constructs

open access: yesArtificial Organs, EarlyView.
The use of autologous connective tissue, such as pericardium or peritoneum, combined with controlled tissue treatment, has the potential to result in a more durable heart valve prosthesis than current commercial prostheses. ABSTRACT Introduction Valvular heart disease remains a leading cause of morbidity and mortality. Current biological and mechanical
Marvin Steitz   +17 more
wiley   +1 more source

Comparison of a Miniaturized Implantable Two‐Stage Rotodynamic Blood Pump to Equivalent Single‐Stage Concepts

open access: yesArtificial Organs, EarlyView.
This study aims to evaluate the potential of a multistage pump design to enhance hemocompatibility in left ventricular assist devices. We found that the two‐stage concept offers favorable hemolysis measures compared to single‐stage designs, as the reduction in peak shear stresses outweighs the disadvantage associated with prolonged residence time ...
Sarah Linnemeier   +6 more
wiley   +1 more source

Identification of Coagulation Phenotypes Using Viscoelastic and Conventional Assays During Veno‐Venous Extracorporeal Membrane Oxygenation: A Hierarchical Clustering Analysis

open access: yesArtificial Organs, EarlyView.
Hierarchical clustering of viscoelastic and conventional coagulation parameters identified three distinct phenotypes in V‐V ECMO patients, revealing substantial APTT–CK‐R discordance and highlighting the value of TEG‐derived markers for detecting coagulopathy not captured by standard monitoring.
Daisuke Irimada   +9 more
wiley   +1 more source