Results 191 to 200 of about 2,108 (264)
Evaluation of Shear Bond Strength and Failure Modes of Lithium Disilicate Ceramic Veneering Material to Different High-Performance Polymers. [PDF]
Alnafaiy SM +7 more
europepmc +1 more source
In this prospective study, a total of 60 patients were divided into three groups of 20 to compare the pressure drop (Δp) across three different oxygenators during cardiopulmonary bypass. The aim of this comparison was to enable evidence‐based optimization of the heart‐lung machine setup in order to minimize potential influencing factors and thereby ...
Jan Turra +9 more
wiley +1 more source
Development and Validation of Customized Silicone Shade Guide for Enhanced Aesthetic Integration in Maxillofacial Prostheses: A Cross-Sectional Study. [PDF]
Pawar P +6 more
europepmc +1 more source
The graphical abstract illustrates our rapid PI‐based spheroid viability assay: hepatocyte spheroids are formed and stained with AO/PI, imaged after a 15‐min incubation, and analyzed for PI brightness normalized to area. This metric correlates strongly with functional urea/DNA output, validating PI intensity as a fast, reliable indicator of spheroid ...
Michael G. Megaly +11 more
wiley +1 more source
We report an insight from the PELS‐1– a multicentre, international registry focusing on postocardiotomy extracorporeal support use between 2000 and 2020. We focused on 24/2163 (1.1%) patients requiring V‐V ECMO after cardiac surgery. Mortality was high, with 21.7% of patients discharged alive and an overall 1‐year survival probability of 12.5 ...
Pasquale Nardelli +39 more
wiley +1 more source
The Effect of Different Storage Conditions on the Physical Properties of Pigmented Medical Grade I Silicone Maxillofacial Material [PDF]
core +1 more source
This study reviews three adverse events during single donor platelet collection using root cause analysis. Causes included human error, equipment defects, and procedural lapses. Though all donors fully recovered, the incidents underscore the need for strict SOP adherence, staff training, and donor safety to maintain trust and donation retention.
Bhagyashri Surve +4 more
wiley +1 more source
Graphical summary of the experimental comparison of shear‐induced hemolysis in pediatric and adult blood using a Couette shearing device. Pediatric blood shows a trend toward lower increase in hemolysis at higher shear stress amplitudes, while no relevant differences are observed at low and intermediate stresses.
Vera Froese +4 more
wiley +1 more source
Patients' Preferences for Bone-Anchored Prostheses After Lower-Extremity Amputation: A 2-Center Discrete Choice Experiment in The Netherlands (PREFER-BAP-1). [PDF]
Saleib GM +6 more
europepmc +1 more source
Size, shape, position and color of Iris: Key to success of an ocular prosthesis
openaire +1 more source

