Results 21 to 30 of about 9,991,044 (292)

Ankle Torque Estimation With Motor Unit Discharges in Residual Muscles Following Lower-Limb Amputation

open access: yesIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2023
There has been increased interest in using residual muscle activity for neural control of powered lower-limb prostheses. However, only surface electromyography (EMG)-based decoders have been investigated.
Noah Rubin   +4 more
doaj   +1 more source

A Comprehensive Review of Myoelectric Prosthesis Control

open access: yesCoRR, 2021
46 ...
MohammadReza Mohebbian   +8 more
openaire   +3 more sources

First Demonstration of Functional Task Performance Using a Sonomyographic Prosthesis: A Case Study

open access: yesFrontiers in Bioengineering and Biotechnology, 2022
Ultrasound-based sensing of muscle deformation, known as sonomyography, has shown promise for accurately classifying the intended hand grasps of individuals with upper limb loss in offline settings.
Susannah M. Engdahl   +9 more
doaj   +1 more source

Multigrasp myoelectric control for a transradial prosthesis [PDF]

open access: yes2011 IEEE International Conference on Rehabilitation Robotics, 2011
This paper presents the design and preliminary experimental verification of a multigrasp myoelectric controller. The controller enables the direct and proportional control of a multigrasp transradial prosthesis through a set of nine postures using two surface EMG electrodes.
Skyler A, Dalley   +2 more
openaire   +2 more sources

Erectile response to intracavernous injection of vasoactive drugs after penile prosthesis removal [PDF]

open access: yes, 1990
Two patients with a history of penile prosthesis removal presented for non-prosthetic treatment of their erectile dysfunction. The first patient had a penile implant for two years before it was removed and showed extensive cavernosal fibrosis. He did not
Stief, Christian Georg   +3 more
core   +1 more source

Datasets of journal paper "Arduino-Based Myoelectric Control: Towards Longitudinal Study of Prosthesis Use"

open access: yes, 2021
This dataset comprises the mean absolute value (MAV) to draw Figure 6 and the normalized MAV to draw Figure 7 in paper "Arduino-Based Myoelectric Control: Towards Longitudinal Study of Prosthesis Use"
Wu, Hancong, Kianoush, Nazarpour
core   +1 more source

Automated Forearm Prosthesis Controlling Using Fiber Bragg Grating Sensor [PDF]

open access: yesJournal of Microwaves, Optoelectronics and Electromagnetic Applications, 2023
This paper describes the automation of a forearm prosthesis using the signal collected by a Fiber Bragg Grating (FBG) sensor. The FBG sensor is applied to one subject's forearm to measure the deformation as a result of the index and middle fingers when ...
Péricles Valera Rialto Júnior   +7 more
doaj   +1 more source

A Novel Framework to Facilitate User Preferred Tuning for a Robotic Knee Prosthesis

open access: yesIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2023
The tuning of robotic prosthesis control is essential to provide personalized assistance to individual prosthesis users. Emerging automatic tuning algorithms have shown promise to ease the device personalization procedure.
Abbas Alili   +6 more
doaj   +1 more source

A walking controller for a powered ankle prosthesis [PDF]

open access: yes2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2014
This paper describes a walking controller implemented on a powered ankle prosthesis prototype and assessed by a below-knee amputee subject on a treadmill at three speeds. The walking controller is a finite state machine which emulates a series of passive impedance functions at the joint in order to reproduce the behavior of a healthy joint.
Amanda Huff Shultz   +5 more
openaire   +3 more sources

A Piezoresistive Sensor to Measure Muscle Contraction and Mechanomyography

open access: yesSensors, 2018
Measurement of muscle contraction is mainly achieved through electromyography (EMG) and is an area of interest for many biomedical applications, including prosthesis control and human machine interface. However, EMG has some drawbacks, and there are also
Daniele Esposito   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy