Results 1 to 10 of about 11,912,514 (216)

Prosthesis design of animal models of periprosthetic joint infection following total knee arthroplasty: A systematic review. [PDF]

open access: yesPLoS ONE, 2019
BACKGROUND:The number of periprosthetic joint infections (PJI) after total knee arthroplasty (TKA) is increasing annually. Animal models have been used to clarify their clinical characteristics and the infection mechanism of pathogenic bacteria, However,
Ke Jie   +5 more
doaj   +3 more sources

Overcoming Challenges and Innovations in Orthopedic Prosthesis Design: An Interdisciplinary Perspective. [PDF]

open access: yesBiomed Mater Devices, 2023
Recent advances in the orthopedic prostheses design have significantly improved the quality of life for individuals with orthopedic disabilities. However, there are still critical challenges that need to be addressed to further enhance the functionality ...
Kulkarni PG   +9 more
europepmc   +2 more sources

Patient-Specific Prosthetic Fingers by Remote Collaboration - A Case Study [PDF]

open access: yesPublic Library of Science, PLoS ONE 6(5):e19508, 2011, 2011
The concealment of amputation through prosthesis usage can shield an amputee from social stigma and help improve the emotional healing process especially at the early stages of hand or finger loss. However, the traditional techniques in prosthesis fabrication defy this as the patients need numerous visits to the clinics for measurements, fitting and ...
A Alison   +31 more
arxiv   +6 more sources

Quantitating the effect of prosthesis design on femoral remodeling using high-resolution region-free densitometric analysis (DXA-RFA). [PDF]

open access: yesJ Orthop Res, 2017
Dual energy X‐ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA).
Farzi M   +7 more
europepmc   +2 more sources

Prosthesis design and placement in reverse total shoulder arthroplasty. [PDF]

open access: yesJ Orthop Surg Res, 2015
The management of irreparable rotator cuff tears associated with osteoarthritis of the glenohumeral joint has long been challenging. Reverse total shoulder arthroplasty (RSA) was designed to provide pain relief and improve shoulder function in patients ...
Ackland DC, Patel M, Knox D.
europepmc   +2 more sources

Three-dimensional-printed customized prosthesis for pubic defect: prosthesis design and surgical techniques [PDF]

open access: yesJournal of Orthopaedic Surgery and Research, 2020
Background This study is to describe the detailed design and surgical techniques of three-dimensional (3D)-printed customized prosthesis for pubic bone defect.
Yuqi Zhang   +8 more
doaj   +2 more sources

Considering passive mechanical properties and patient user motor performance in lower limb prosthesis design optimization to enhance rehabilitation outcomes. [PDF]

open access: yesPhys Ther Rev, 2017
Background: Selection of prosthesis mechanical characteristics to restore function of persons with lower limb loss can be framed as an optimization problem to satisfy a given performance objective.
Major MJ, Fey NP.
europepmc   +2 more sources

The Influence of Custom-Milled Framework Design for an Implant-Supported Full-Arch Fixed Dental Prosthesis: 3D-FEA Sudy [PDF]

open access: yesInternational Journal of Environmental Research and Public Health, 2020
The current study aimed to evaluate the mechanical behavior of two different maxillary prosthetic rehabilitations according to the framework design using the Finite Element Analysis.
João Paulo Mendes Tribst   +6 more
semanticscholar   +3 more sources

Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs. [PDF]

open access: yesSci Rep, 2016
Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations.
Handford ML, Srinivasan M.
europepmc   +2 more sources

Robot milling system integrated design and finite element analysis of custom femoral prostheses [PDF]

open access: yesJournal of Orthopaedic Surgery and Research
The long-term stability of cementless femoral prostheses is primarily affected by aseptic loosening, micromotion, and stress shielding, all of which are related to the force transfer of the prosthesis. These factors can compromise the osseointegration of
Qi Wu   +5 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy