Results 11 to 20 of about 128,209 (331)
Validation of an MRI Technique for the 6-DOF Knee Kinematics Measurement
Background: For total knee arthroplasty (TKA), the optimal rotational position of the femoral component is felt to be critically important. The current knee joint kinematics measurement technology is unable to identify the exact rotation axis of the knee
Shixiong Tang +6 more
doaj +1 more source
Background: The purpose of this in vitro study is to fabricate a novel metal–ceramic prosthesis with a porous structure, to compensate for the disadvantages associated with the design of existing prostheses, and to measure the internal fit of this ...
Eun-Jeong Bae +2 more
doaj +1 more source
A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems [PDF]
Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate ...
Boere, Daphne +5 more
core +4 more sources
Designing special prosthesis "Spacer"
Malignant diseases of the medial part of the femur, humerus and tibia, treated with surgical removal of the affected part of the bone and prosthesis fitting special "Spacer". This type of prosthesis is made in the form of the proximal and distal components that connect by screws.
Jovan, Grujić +8 more
openaire +3 more sources
Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis [PDF]
Background and aim: Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision.
Buzayan, M. M.
core +2 more sources
An Analysis of Theories in Biomechanics
The nature of the systems commonly thought of as coming into the remit of biomechanics range from 'mechanical' systems (concerned with the design of medical devices, such as implants) to 'mechanobiological' systems (concerned with the response of tissues,
P.J. Prendergast
doaj +1 more source
This work addresses the design, analysis, and validation of a transtibial custom prosthesis. The methodology consists of the usage of videometry to analyze angular relationships between joints, moments, and reaction forces in the human gait cycle.
Marco Antonio Hernández-Acosta +5 more
doaj +1 more source
The Effects of Interlocking a Universal Hip Cementless Stem on Implant Subsidence and Mechanical Properties of Cadaveric Canine Femora. [PDF]
ObjectiveTo determine if an interlocking bolt would limit subsidence of the biological fixation universal hip (BFX(®)) femoral stem under cyclic loading and enhance construct stiffness, yield, and failure properties.Study designEx vivo biomechanical ...
Buks, Yonathan +3 more
core +1 more source
Effects of prosthetic design parameters on running performance of a unilateral transfemoral amputee
Carbon fiber running-specific prostheses (RSPs) are widely used among lower-limb amputee runners. However, which prosthesis provides the best performance for runners remains unknown.
Cem GUZELBULUT +3 more
doaj +1 more source
Finite element analysis of porously punched prosthetic short stem virtually designed for simulative uncemented hip arthroplasty [PDF]
Background: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically.
Bai, Bo +4 more
core +3 more sources