Results 11 to 20 of about 11,912,514 (216)

An innovative total temporomandibular joint prosthesis with customized design and 3D printing additive fabrication: a prospective clinical study

open access: yesJournal of Translational Medicine, 2019
Background Total temporomandibular joint (TMJ) prosthesis is an effective and reliable method of joint reconstruction. However, there is still an urgent need to design a new TMJ prosthesis because of no commercially available TMJ prosthesis appropriate ...
JiSi Zheng   +5 more
doaj   +2 more sources

A digital patient for computer-aided prosthesis design. [PDF]

open access: yesInterface Focus, 2013
This article concerns the design of lower limb prosthesis, both below and above knee. It describes a new computer-based design framework and a digital model of the patient around which the prosthesis is designed and tested in a completely virtual ...
Colombo G, Facoetti G, Rizzi C.
europepmc   +2 more sources

Research progress on the design of fixed implant-supported prostheses in edentulous jaws

open access: yes口腔疾病防治, 2022
With the aging of the population and the increase in the number of edentulous patients, implant-supported fixed restorations have become more prevalent in clinical treatment.
LIU Shiyao, YAN Qi, SHI Bin
doaj   +1 more source

New technologies applied to canine limb prostheses: A review [PDF]

open access: yesVeterinary World, 2021
Although only a few studies have investigated about the development of animal prosthesis, currently, there is an increasing interest in canine limb prosthesis design and its clinical application since they offer an alternative to killing the animal in ...
Paul G. Arauz   +4 more
doaj   +1 more source

Evaluation of internal fit of press ceramic and porous structured cobalt–chromium crown fabricated by additive manufacturing

open access: yesDental Research Journal, 2022
Background: The purpose of this in vitro study is to fabricate a novel metal–ceramic prosthesis with a porous structure, to compensate for the disadvantages associated with the design of existing prostheses, and to measure the internal fit of this ...
Eun-Jeong Bae   +2 more
doaj   +1 more source

Validation of an MRI Technique for the 6-DOF Knee Kinematics Measurement

open access: yesFrontiers in Bioengineering and Biotechnology, 2022
Background: For total knee arthroplasty (TKA), the optimal rotational position of the femoral component is felt to be critically important. The current knee joint kinematics measurement technology is unable to identify the exact rotation axis of the knee
Shixiong Tang   +6 more
doaj   +1 more source

Study of composite elastic elements for transfemoral prostheses: the MyLeg Project [PDF]

open access: yes, 2022
In this thesis, the work on the design and realization of a semi-active foot prosthesis with variable stiffness system is presented. The final prosthesis was the result of a path started by the design of the elastic composite elements of an ESR ...
Tabucol, Johnnidel
core   +1 more source

Detecting total hip replacement prosthesis design on plain radiographs using deep convolutional neural network [PDF]

open access: yesJournal of Orthopaedic Research, 2019
Identifying the design of a failed implant is a key step in the preoperative planning of revision total joint arthroplasty. Manual identification of the implant design from radiographic images is time‐consuming and prone to error. Failure to identify the
Alireza Borjali   +4 more
semanticscholar   +1 more source

Relative motion at the bone-prosthesis interface [PDF]

open access: yes, 1994
Bone ingrowth in porous surfaces of human joint implants is a desired condition for long-term fixation in patients who are physically active (such as in sport or work). It is generally recognized that little actual bone ingrowth occurs. The best clinical
Grootenboer, H.J.   +3 more
core   +19 more sources

Home - About - Disclaimer - Privacy