Left Ventricular Outflow Tract Geometry as a Predictor of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation Using the Evolut Series

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Predicting the need for permanent pacemaker implantation (PPM) after transcatheter aortic valve implantation (TAVI) is crucial for procedural planning and patient counseling. Aims To evaluate whether left ventricular outflow tract (LVOT) morphology, specifically a tapered configuration, predicts conduction disturbances requiring PPM
Mahmoud Abdelshafy   +13 more
wiley   +1 more source

Predicting Coronary Occlusion Risk during Redo‐TAVR at First TAVR: Asymmetric Calcification Causes Failure

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background and Aims Predicting coronary artery occlusion due to sinus sequestration (SS) during a second transcatheter aortic valve (TAV) procedure using pre‐procedural computed tomography (CT) after the first TAV replacement (TAVR) is underreported.
Kyohei Onishi   +12 more
wiley   +1 more source

Analysis of aortic valve prostheses using advanced cardiovascular imaging-a patient-specific reversed translational approach. [PDF]

open access: yesSci Rep
Grefen L   +13 more
europepmc   +1 more source

Intra‐Annular Versus Supra‐Annular Self‐Expanding Valves for Valve‐in‐Valve TAVR

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background A limitation of Valve‐in‐Valve (VIV) transcatheter aortic valve replacement (TAVR) is patient‐prosthesis mismatch (PPM), which is associated with worse quality of life and heart failure hospitalizations. As such, strategies to avoid PPM are desired. We compared the clinical and hemodynamic results of VIV TAVR with intra‐annular self‐
John T. Saxon   +19 more
wiley   +1 more source

The Verification of Co‐Axiality of the Three Self‐Expanding Transcatheter Aortic Valve Systems According to the Difference in Shaft Spine

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Accurate bioprosthesis implantation depth during transcatheter aortic valve replacement (TAVR) is crucial for optimal outcomes. Self‐expanding valves (SEVs) have evolved delivery catheter designs, from a double spine shaft in Evolut PRO+ (PRO + ) to single spine in Evolut FX (FX) and non‐spine in Navitor, to improve access ...
Yun Teng   +13 more
wiley   +1 more source

Understanding the Workflows in Non-Guided and Static Computer-Assisted Implant Surgery. [PDF]

open access: yesClin Exp Dent Res
Jorba-Garcia A   +6 more
europepmc   +1 more source

Long‐Term Impact of Prosthesis‐Patient Mismatch After Transcatheter Aortic Valve Replacement in Patients With Small Aortic Annuli

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Prosthesis‐patient mismatch (PPM) remains common following transcatheter aortic valve replacement (TAVR) and is associated with worse clinical outcomes. PPM is of particular concern in small aortic annuli (SAA). Aims To compare the incidence, predictors, and long‐term impact of PPM in SAA TAVR.
Itamar Loewenstein   +9 more
wiley   +1 more source

Biomechanical study of screw-supported prosthesis in acetabular revision. [PDF]

open access: yesBone Joint Res
Wan Q   +8 more
europepmc   +1 more source

Annular Ellipticity and Sizing Strategy in Transcatheter Aortic Valve Implantation: Independent or Combined Risk Patterns?

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Elliptical annular anatomy has been considered a risk factor for adverse outcomes after TAVI, particularly paravalvular leakage (PVL). Prosthesis oversizing is thought to improve sealing, but the interaction between annular shape and sizing strategy remains unclear.
Emre Polat   +6 more
wiley   +1 more source