Results 21 to 30 of about 11,912,514 (216)
The loosening of traditional prosthetics is among the leading causes of surgical failure of proximal femoral bone defects. A novel compound sleeve and stem prosthesis was designed using an optimization methodology that combined an octet-truss porous ...
Haowen Xue+7 more
doaj +1 more source
Biomechanical Hand Prosthesis Design
There are various studies on the structural and functional constructions of hand prostheses inspired by human biomechanics, and there are different kinds of prostheses available on the market. This paper aims to present the relevant stages of designing a
Emilia Furdu Lunguţ+4 more
doaj +1 more source
Effects of prosthetic design parameters on running performance of a unilateral transfemoral amputee
Carbon fiber running-specific prostheses (RSPs) are widely used among lower-limb amputee runners. However, which prosthesis provides the best performance for runners remains unknown.
Cem GUZELBULUT+3 more
doaj +1 more source
A Piecewise Monotonic Gait Phase Estimation Model for Controlling a Powered Transfemoral Prosthesis in Various Locomotion Modes [PDF]
Gait phase-based control is a trending research topic for walking-aid robots, especially robotic lower-limb prostheses. Gait phase estimation is a challenge for gait phase-based control. Previous researches used the integration or the differential of the human's thigh angle to estimate the gait phase, but accumulative measurement errors and noises can ...
arxiv +1 more source
This work addresses the design, analysis, and validation of a transtibial custom prosthesis. The methodology consists of the usage of videometry to analyze angular relationships between joints, moments, and reaction forces in the human gait cycle.
Marco Antonio Hernández-Acosta+5 more
doaj +1 more source
Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis [PDF]
Background and aim: Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision.
Buzayan, M. M.
core +2 more sources
Finite element analysis of porously punched prosthetic short stem virtually designed for simulative uncemented hip arthroplasty [PDF]
Background: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically.
Bai, Bo+4 more
core +2 more sources
Patients with oral cancer often have to undergo the surgery for mandibular excision. Once the bone in the cancerous area is removed, not only the facial area but also chewing function of the patient is needed to be repaired by clinicians. In recent years,
Sheng-Ni Huang+5 more
doaj +1 more source
DEVELOPMENT OF A METHOD FOR CALCULATING LOADS ON IMPLANTS AND PROSTHESES USED FOR THE HUMAN SKELETON
The study proposes a novel computational approach for customizing sustainable knee disarticulation prostheses, aimed at improving the quality of life for users. A specialized calculation technique for assessing the loads and moments on the prosthesis was
Ismet Emircan Tunc, Gürsel Şefkat
doaj +1 more source
A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems [PDF]
Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate ...
Boere, Daphne+5 more
core +4 more sources