Results 51 to 60 of about 11,912,514 (216)

The Design and Testing of a PEA Powered Ankle Prosthesis Driven by EHA

open access: yesBiomimetics, 2022
Several studies have shown that actuation concepts such as Serial elastic actuator (SEA) can reduce peak power and energy consumption in ankle prostheses.
Qitao Huang, Bowen Li, Hongguang Xu
doaj   +1 more source

VIBES: Vibro-Inertial Bionic Enhancement System in a Prosthetic Socket [PDF]

open access: yes, 2023
The use of vibrotactile feedback is of growing interest in the field of prosthetics, but few devices fully integrate this technology in the prosthesis to transmit high-frequency contact information (such as surface roughness and first contact) arising from the interaction of the prosthetic device with external items.
arxiv   +1 more source

A Compact, Lightweight Robotic Ankle-Foot Prosthesis: Featuring a Powered Polycentric Design

open access: yesIEEE robotics & automation magazine, 2020
Robotic ankle-foot prostheses aim to improve the mobility of individuals with belowknee amputations by closely imitating the biomechanical function of the missing biological limb. To accomplish this goal, they must provide biomechanically accurate torque
Lukas Gabert   +4 more
semanticscholar   +1 more source

"All on short" prosthetic-implant supported rehabilitations [PDF]

open access: yes, 2017
Objectives. Short implants are increasing their popularity among clinicians who want to fulfill the constant demanding of fixed prosthetic solutions in edentulous jaws.
Bernardi, S.   +6 more
core   +1 more source

The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis

open access: yesIEEE Transactions on Neural Systems and Rehabilitation Engineering
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions.
Johnnidel Tabucol   +10 more
doaj   +1 more source

Rehabilitation of squamous cell carcinoma defect with two‐piece hollow bulb obturator prosthesis – A case report

open access: yesClinical Case Reports, 2021
Two‐piece hollow bulb obturator maxillofacial prosthesis for hemi‐maxillectomy defect is given after surgical resection due to oral squamous cell carcinoma. Maxillofacial prosthodontists play a pivotal role in construction of prosthesis.
Anitha Kuttae Viswanathan   +1 more
doaj   +1 more source

De novo topology optimization of Total Ossicular Replacement Prostheses [PDF]

open access: yesJournal of the Mechanical Behavior of Biomedical Materials, 2020, 103, 103541, 2020
Conductive hearing loss, due to middle ear pathologies or traumas, affects more than 5% of the population worldwide. Passive prostheses to replace the ossicular chain mainly rely on piston-like titanium and/or hydroxyapatite devices, which in the long term suffer from extrusion.
arxiv   +1 more source

Pembersih bilah kipas siling [PDF]

open access: yes, 2020
Kebanyakan rumah pada kebiasaannya mempunyai kipas siling tidak kira samada rumah moden atau tradisional. Kipas siling merupakan sejenis kipas yang digantung pada bahagian atas rumah untuk mengitar udara melalui bilah-bilah kipas berputar (Norfarahanim ...
Abdul Halim, Muhammad Hazim   +5 more
core  

Myoelectric forearm prostheses: State of the art from a user-centered perspective [PDF]

open access: yes, 2011
User acceptance of myoelectric forearm prostheses is currently low. Awkward control, lack of feedback, and difficult training are cited as primary reasons.
Boere, Daphne   +8 more
core   +2 more sources

Is The Size of the Currently Available Implants for Total Hip Arthroplasty Adequate for Our Population?

open access: yesRevista Brasileira de Ortopedia
Objective To determine if the dimensions of selected national and imported implants used in total hip arthroplasty surgeries are adequate regarding the anthropometric profile of the Brazilian population.
Thiago Sampaio Busato   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy