Corrosion fatigue failure of a high carbon CoCrMo modular hip prosthesis: Failure analysis and electrochemical study

Engineering Failure Analysis, 2019
A. Lanzutti   +6 more
semanticscholar   +1 more source

A software tool for prediction of prosthesis failure at the carpometacarpal joint of the thumb

Journal of Hand Surgery (European Volume), 2015
A. Tandara   +5 more
semanticscholar   +1 more source

Metallurgical aspects of failure in a broken femoral HIP prosthesis

Engineering Failure Analysis, 2018
M. K. Khouzani, A. Bahrami, A. Eslami
semanticscholar   +1 more source

Ossiculoplasty failure with ceramic ossicular replacement prosthesis.

ORL; journal for oto-rhino-laryngology and its related specialties, 1987
The stability of ceramic ossicular replacement prosthesis (CORP) in the middle ear was evaluated in 162 ears that had been followed for more than 18 months. The CORP extruded from 8 ears (4.9%) and was dislocated in 6 ears (3.7%). These failures were considered to be due mainly to postoperative tubal dysfunction and disease recurrence.
E, Yamamoto, M, Iwanaga
openaire   +1 more source

Polyethylene failure in a PCA unicompartmental knee prosthesis

Acta Orthopaedica Scandinavica, 1990
O M, Christensen   +2 more
openaire   +2 more sources

The impact of amount of bone resection on uncemented prosthesis failure in patients with a distal femoral tumor

Journal of Surgical Oncology, 2011
W. Song   +6 more
semanticscholar   +1 more source

Disc failure in a Björk-Shiley mitral prosthesis.

The Journal of heart valve disease, 1995
The case of a 50-year-old man is presented who underwent reoperation for a malfunctioning Björk-Shiley spherical valve which had been inserted 14 years previously. The patient made a satisfactory recovery after surgery. Examination of the explanted valve revealed that a segment of the pyrolytic carbon disc was missing.
C, Van Sabben, S C, Griffin, G E, Venn
openaire   +1 more source

Patterns of failure in the original Besser bipolar prosthesis.

South African journal of surgery. Suid-Afrikaanse tydskrif vir chirurgie, 1990
Fourteen original Besser endoprostheses inserted in young patients with osteonecrosis of the femoral head were reviewed. Two cups dislocated early and 1 other required replacement due to acetabular degeneration. Component disassembly occurred in 4 hips, which had exhibited persistently vertical cups.
A W, Heywood, G W, Keys
openaire   +1 more source

The pathology of the joint tissues and its clinical relevance in prosthesis failure.

Clinical Orthopaedics and Related Research, 1976
J. Mirra, H. Amstutz*, M. Matos, R. Gold
semanticscholar   +1 more source

Murine model of prosthesis failure for the long‐term study of aseptic loosening

Journal of Orthopaedic Research, 2007
Shang-You Yang   +6 more
semanticscholar   +1 more source