Results 1 to 10 of about 1,608,246 (233)
Heart valve replacements improve symptoms and life expectancy but may have potential problems. Biological replacements have limited durability but do not require anticoagulation and are usually used for the relatively elderly. Mechanical valves have a virtually zero primary failure rate but require anticoagulation and are usually used for the ...
Demosthenes G. Katritsis +2 more
core +4 more sources
Prosthetic heart valves are commonly used as a treatment for aortic valve deficiencies. The performance of these prosthetic valves should be in accordance with the natural heart valve with respect to opening and closing, blood flow, and vortex formation.
Jaafar Ghanbari +2 more
doaj +3 more sources
Pregnant Woman in Outcomes with Prosthetic Heart Valves [PDF]
We here sought to assess thrombotic and hemorrhagic complications and associated risk factors during pregnancy, delivery, and postpartum in women with prosthetic heart valves (PHV). Methods: The retrospective cohort study covered January 2011 to December
Giunai Sefiyeva +10 more
doaj +2 more sources
Rapid Native and Bioprosthetic Tricuspid Valve Degeneration in Carcinoid Heart Disease [PDF]
Background: Carcinoid heart disease (CaHD) is a severe complication of metastatic neuroendocrine tumors characterized by serotonin-mediated fibrotic degeneration of right-sided cardiac valves.
Lucia Trabucchi, MS +9 more
doaj +2 more sources
Systemic thrombolysis for mechanical prosthetic valve thrombosis - case report and review of literature [PDF]
Prosthetic valve thrombosis is one of the life-threatening complications in patients with prosthetic heart valves. It is more common in mechanical prosthetic valves in the setting of inadequate or missing anticoagulation.
E. Dimitrova +4 more
doaj +3 more sources
A 55-year-old invasive/clinical cardiologist worked full time, exercised regularly, and was asymptomatic. Two weeks previously, he had new onset of angina on exertion. Echocardiography/Doppler and cardiac catheterization confirmed the clinical assessment of severe aortic stenosis with a valve area of 0.5 cm2/m2.
Grace, Huang, Shahbudin H, Rahimtoola
openaire +2 more sources
Anticoagulation During Pregnancy with a Mechanical Pulmonary Valve: Patient and Medical Perspective
This article discusses the challenges of supporting a successful pregnancy in a woman with multiple prosthetic heart valves and a complicated cardiac history, from both the patient and provider perspective.
Lauren Ledingham +2 more
doaj +1 more source
Prosthetic Heart Valves and Pregnancy [PDF]
In patients with prosthetic heart valves (PHV), pregnancy is associated with the risks of warfarin embryopathy in patients with mechanical PHV and of structural valve deterioration (SVD), both early and late, in patients with biological PHV. ### Warfarin The use of warfarin, particularly between the 6th and 12th weeks of pregnancy, is associated with
Lynne, Hung, Shahbudin H, Rahimtoola
openaire +2 more sources
Optimization of anticoagulant therapy in patients undergoing mechanical heart valve replacement
Acquired heart defects have a high prevalence among patients of different age groups and represent a significant social problem. To date, surgery remains the only effective option to treat acquired heart disease, and replacement of the dysfunctional ...
S. A. Tkachenko +7 more
doaj +1 more source
Management of Prosthetic Tricuspid Valve Thrombosis with Streptokinase
Despite improvements in the design of mechanical prosthetic heart valves and regular use of anticoagulation, prosthetic heart valve thrombosis remain the most dreadful complication associated with high mortality.
Azizullah +4 more
doaj +1 more source