Results 91 to 100 of about 326,823 (244)

Valvular Hemolysis Masquerading as Prosthetic Valve Stenosis

open access: yes, 2017
The evaluation of prosthetic valves can provide a unique challenge, and a thoughtful approach is required. High output states like anemia should be kept in the differential when evaluating elevated gradients across prosthetic valves.
Rahman, Zia   +11 more
core   +1 more source

New and Emerging Artificial Urinary Sphincters for Male Stress Urinary Incontinence: From Gold Standard to Next Generation

open access: yesNeurourology and Urodynamics, EarlyView.
ABSTRACT Introduction For more than four decades, the AMS‐800 has remained the clinical benchmark device for the treatment of male stress urinary incontinence (SUI). Although it remains the gold standard for male SUI, the AMS‐800 has continued to have limitations such as suboptimal post‐operative continence rates, fixed hydraulic pressure, need for ...
Erin C. Schnell   +2 more
wiley   +1 more source

Enhanced Recovery After Surgery in Simultaneous Pancreas–Kidney Transplantation: A Retrospective Cohort Analysis of Perioperative Outcomes

open access: yesOrgan Medicine, EarlyView.
ABSTRACT Background While simultaneous pancreas–kidney transplantation (SPK) is an established therapeutic intervention for patients with end‐stage renal disease and diabetes, it has been associated with prolonged recovery periods and high complication rates.
Rongxin Chen   +5 more
wiley   +1 more source

Characteristics, properties and limitations of per‐ or polyfluoroalkyl substances (PFASs) and fluoropolymers

open access: yesPolymer International, EarlyView.
An overview and categorization of man‐made per‐ or polyfluoroalkyl substances (PFASs) including low‐molar‐mass and high‐molar‐mass fluorochemicals, and their international regulations is presented. Though certain PFASs are toxic, bioaccumulative and cross the human cellular membranes, others, such as fluoropolymers, are safe, reliable and involved in ...
Bruno Améduri
wiley   +1 more source

Unusual mechanism of myocardial infarction in prosthetic valve endocarditis

open access: yes, 2015
Fernando A Atik,1 Vanessa G Campos,2 Claudio R da Cunha,1 Felipe Bezerra Martins de Oliveira,1 Maria Estefânia Bosco Otto,2 Guilherme U Monte,2 1Department of Cardiovascular Surgery, Instituto de Cardiologia do Distrito Federal, Fundaç ...
Monte GU   +5 more
core  

Continuous‐Flow Left Ventricular Assist Devices in Biventricular Configuration: A Systematic Review and Comparative Meta‐Analysis of HeartMate 3 and HeartWare Biventricular Assist Devices

open access: yesArtificial Organs, EarlyView.
HeartWare‐BiVAD was associated with more frequent right ventricular cannulation, whereas HM3‐BiVAD demonstrated a trend toward improved survival despite a more severe preimplant clinical profile, suggesting a potential device‐related advantage of HM3 in biventricular support.
Daler Rahimov   +10 more
wiley   +1 more source

Pannus-Related Mechanical Valve Dysfunction Leading to Hemodynamic Shock

open access: yesArchives of Clinical and Experimental Surgery, 2012
Mechanical prosthetic valve dysfunction caused by pannus formation is rare. Pannus restricts movement of prosthetic valve leaflets, resulting in severe aortic regurgitation.
Manabu Shiraishi   +6 more
doaj   +1 more source

In vitro investigations on prosthetic valve thrombosis by ultrasound phonocardiography

open access: yes, 2013
OBJECTIVE: Prosthetic valve thrombosis is a serious complication associated with high morbidity and mortality; the early detection of thrombotic formations is crucial for prompt diagnosis and proper therapy. METHODS: Thrombotic deposits were simulated in
PENGO, VITTORIO   +7 more
core  

Urokinase therapy for Bjork-Shiley prosthetic valve thrombosis Part I: Studies on clinical findings and maximum opening angle of prosthetic valve [PDF]

open access: yes, 1988
Urokinase was administrated to 36 patients for the thrombolytic treatment of 63 instances of Bjork-Shiley prosthetic valve thrombosis. Patients were diagnosed either from clinical findings or from the maximum opening angle of the prosthetic valve.
Suga, Masakazu
core  

Home - About - Disclaimer - Privacy