Results 71 to 80 of about 1,270,030 (169)
Introduction: The aim of this in-vitro study was to use dye penetration method to compare the apical microleakageof matched taper single-cone and cold lateral condensation technique in teeth prepared with ProTaper instruments. Materials and Methods:
Khurram Parvez +4 more
doaj
Introduction: One of the important factors contributing to the success of nonsurgical endodontic retreatment is the efficient removal of the obturating material from the root canal space. However, the fracture resistance of the tooth is likely to be affected by this procedure.
Isha Singh +5 more
openaire +1 more source
Transportation and Centering Ability of Neoniti and ProTaper Instruments; A CBCT Assessment [PDF]
Introduction: Transportation is an important iatrogenic endodontic error which might cause failure. This study evaluated the canal transportation caused by Neoniti and ProTaper instruments, using cone-beam computed tomography (CBCT) cross sections ...
Soleymani, Ali +5 more
core +1 more source
The Intra-Manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometer [PDF]
Introduction: As an attempt to simplify the obturation process and create a tight seal, manufacturers offer gutta-percha (GP) cones matching different sizes of endodontic files.
Mirmohammadi, Hesam +2 more
core +1 more source
Background: Effective endodontic instrumentation aims to remove microorganisms, debris, and tissue from the root canal while maintaining dentinal integrity.
Hiral Milap Karia +5 more
doaj +1 more source
This in vitro study aims to assess the cyclic fatigue resistance of the Protaper Ultimate (PTU) files compared to the Protaper Gold (PTG) and the M3 UDG (M3) files using various motion kinematics in simulated canals.
Cezar Tiberiu Diaconu +8 more
doaj +1 more source
To evaluate the effectiveness of the ProTaper and Mtwo retreatment systems for removal of resin-based obturation techniques during retreatment. A total of 160 maxillary anterior teeth were enlarged to size 30 using ProTaper and Mtwo rotary instruments ...
İRİBOZ, EMRE, SAZAK ÖVEÇOĞLU, HESNA
core +1 more source
Cyclic fatigue resistance of different continuous rotation and reciprocating endodontic systems
Objective: The objective of this study is to compare the cyclic fatigue resistance of nine types of endodontic instruments of nickel–titanium. Materials and Methods: Five files of 25 mm of length of each group: Reciproc (RC) R25; WaveOne (WO) Primary ...
Fabio de Almeida-Gomes +6 more
doaj +1 more source
Aim: This study compared the efficacy of ProFile Vortex (PV) with that of ProTaper Next (PTN) for the removal of root canal filling material. Materials and methods: Twenty-six mesial canals of extracted mandibular first molars were instrumented ...
Emad AlShwaimi
doaj +1 more source
Comparison of Protaper, Medin and RaCe rotary files breaking time in vitro study with RC-prep Lubricant and Sodium Hypochlorite Washing [PDF]
Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the purpose of this study is Compare of Protaper, Medin and RaCe rotary files breaking time ...
زاد فتاح, فیروز +1 more
core

