A lack of standard approaches for testing and reporting the performance of metal halide perovskites and organic semiconductor radiation detectors has resulted in inconsistent interpretation of performance parameters, impeding progress in the field. This Perspective recommends key metrics and experimental details, which are suggested for reporting in ...
Jessie A. Posar +8 more
wiley +1 more source
Objective Evaluation of Pulse Width Using an Array Pulse Diagram
Background Pulse width, which can reflect qi , blood excess, and deficiency, has been used for diagnosing diseases and determining the prognosis in traditional Chinese medicine (TCM).
Zi-Juan Bi PhD +7 more
doaj +1 more source
Energy Saving in Permanent Cardiac Pacing: Pulse Waveform and Charge Balancing Deserve Consideration
The pacing pulse produced by implantable stimulators can be described as a truncated exponential decay from the starting peak amplitude, corresponding to the discharge of the output stage capacitance (reservoir and isolation capacitors, in series) along ...
Franco Di Gregorio +4 more
doaj +1 more source
Introduction: The microcirculation of the lower limbs (LL) of diabetics is influenced by hyperglycemia and several factors (hypertension, obesity, dyslipidemia) leading to the functional and later the structural changes, manifesting as dysregulation of ...
Hubena G. +3 more
doaj +1 more source
In This paper, a high power sub-nanosecond pulse transmitter for Ultra-wideband radar sensor is presented. The backbone of the generator is considered as a step recovery diode and unique pulse injected into the circuit, which gives rise to an ultra-wide ...
Y. Ahajjam +4 more
doaj +1 more source
Isolated output for class-D dc amplifiers [PDF]
Transformer-coupled output stage is used with pulse-width modulated class-D dc amplifiers. Circuit is comprised of two channels corresponding to negative and positive input signals.
Honnel, M. A., Newell, J. K.
core +1 more source
Abstract Objective. The vestibular implant is a potential treatment approach for bilateral vestibulopathy patients. To restore gaze stabilization, the implant should elicit vestibulo-ocular reflexes (VORs) over a wide range of eye velocities.
van Boxel, Stan C J +6 more
openaire +4 more sources
This work discusses the use of blended channel materials in OECTs. It explores how mixing glycolated and alkoxylated polymers in various ratios offers a simpler and more efficient route to tuning OECT properties. The performance of the polymer blends is compared to the corresponding copolymers, demonstrating similar OECT characteristics, swelling ...
Lize Bynens +14 more
wiley +1 more source
Noninvasive Point of Care Device for Assessing Cardiac Response to Acute Volume Changes
Harry A Silber,1 Nisha A Gilotra,1 Thomas L Miller2,3 1Department of Medicine, Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA; 2Enalare Therapeutics, Inc, Princeton, NJ, USA; 3Department of Pediatrics, Sidney ...
Silber HA, Gilotra NA, Miller TL
doaj
Novel ferrocene derivatives (e.g., FcPhc2) are used as an ultrathin layer hole‐blocking layer, reducing hole injection from the Ag contact. This results in an ultralow noise spectral density of 1.2 × 10−14 A Hz−1/2, and a high specific detectivity of 8.1 × 1012 Jones at −0.5 V.
Eunyoung Hong +16 more
wiley +1 more source