Results 91 to 100 of about 544,514 (286)
Determining factors of pulse oximetry accuracy: a literature review
Objective: Identify and reach consensus on the variables that affect the measurement of oxygensaturation using pulse oximetry. Methods: We applied inclusion and exclusion criteria to select relevant studies in databasessuch as Ebsco and PubMed.
Barrio Mateu, L.A. +7 more
core +1 more source
Abstract Polysomnography (PSG), the reference standard for sleep assessment, has limited scalability for large‐scale screening, driving the development of wearable and unobtrusive monitors. However, the physiological signals these devices capture are physiologically correlated with PSG channels but are not completely equivalent.
Jing Yan +5 more
wiley +1 more source
Pulse oximetry for perioperative monitoring
BACKGROUND: This is an update of a review last published in Issue 9, 2009, of The Cochrane Library. Pulse oximetry is used extensively in the perioperative period and might improve patient outcomes by enabling early diagnosis and, consequently ...
Pedersen, Tom +11 more
core +1 more source
ABSTRACT Sargassum inundation of Caribbean and American shorelines is a growing environmental hazard. Hydrogen sulfide (H2S) and ammonia (NH3) produced by decomposing Sargassum could be involved in airway obstruction and bronchial inflammation. The study was undertaken to evaluate the effects of exposure to H2S and NH3 gases emitted during Sargassum ...
Rishika Banydeen +9 more
wiley +1 more source
Abstract Background Perioperative analgesia is essential in dogs undergoing orthopaedic surgery, and enflicoxib's long duration makes single‐dose administration attractive. Methods A prospective, multicentre, randomised, masked trial compared enflicoxib (8 mg/kg) given 24 hours before surgery with firocoxib (5 mg/kg) given daily for 7 days. Two hundred
Marta Salichs +4 more
wiley +1 more source
Pulse oximetry: Evaluation of a potential tool for early detection of critical congenital heart disease [PDF]
Background: About one third of newborns with life-threatening congenital heart disease leave newborn nurseries without the problem being recognized, and risk death or serious damage from circulatory collapse.
de-Wahl Granelli, Anne
core
Abstract The Internet of Things (IoT) in deploying robotic sprayers for pandemic‐associated disinfection and monitoring has garnered significant attention in recent research. The authors introduce a novel architectural framework designed to interconnect smart monitoring robotic devices within healthcare facilities using narrowband Internet of Things ...
Md Motaharul Islam +9 more
wiley +1 more source
Pulse oximetry provides a rapid, non-invasive assessment of haemoglobin oxygen saturation using light absorption principles. Modern devices are accurate to ±2% but become less reliable at low saturations.
core +1 more source
What Outcomes Matter in Vital Pulp Therapy? Current Concepts and Challenges
ABSTRACT Vital pulp therapy (VPT) has re‐emerged as a practical and biologically sound alternative for managing deep caries and carious pulp exposures. Although its clinical use is now widespread, the outcomes used to judge the success of VPT remain inconsistent and often difficult to compare across studies.
Philip Yuan‐Ho Chien +5 more
wiley +1 more source
FINGER VERSUS FOREHEAD PULSE OXIMETRY IN LITERATURE: A NARRATIVE REVIEW
Introduction: Pulse oximetry is a technology for monitoring oxygen saturation (SpO2) in various clinical settings. However, measurement of SpO2 value can have different accuracy depending on some factors such as the sensor placement (on the finger or on ...
Rita Citarella +3 more
doaj +1 more source

