Results 231 to 240 of about 5,075,819 (283)

Current‐Induced Domain Wall Dynamics in Pt/Co/Ni/Co Nanoribbons With Curvilinear Cross‐Sections

open access: yesAdvanced Materials, EarlyView.
3D curvilinear magnetic racetrack nanoribbons are formed with concave and convex cross‐sections using an advanced multi‐photon 3D printer. The curvature is shown to strongly affect current‐induced domain wall motion along the nanoribbons. In nanoribbons with cross‐sections that have both concave and convex segments, the velocities of domain walls with ...
Tiange Dong   +6 more
wiley   +1 more source

Inductively Expandable Supraparticles as Microscopic Force Generators for Remote Mechanical Actuation

open access: yesAdvanced Materials, EarlyView.
This study demonstrates the combination of magnetic nanoparticles and functional blowing agents into supraparticles. Upon induction heating, they actuate via rapid gas generation or extensive volume expansion. These supraparticles lift up to 25 000 times their own mass and rapidly open cured epoxy resins, providing a versatile strategy for fast micron ...
Leoni Luthardt   +3 more
wiley   +1 more source

Poly(Alkoxythiophene) Rod‐Coil Block Copolymers for Organic Electrochemical Transistors

open access: yesAdvanced Materials, EarlyView.
We present the first synthesis of poly(3‐alkoxythiophene) rod‐coil block copolymers as a new architecture for OMIECs. Incorporating PEG and PLLA coils can enhance device performance beyond the homopolymer. The figure‐of‐merit depends uniquely on coil length.
Junfu Tian   +23 more
wiley   +1 more source

Strong Coupling in Bulk Nanoplasmonic Nanoplatelet Perovskite Scintillators

open access: yesAdvanced Materials, EarlyView.
A bulk scintillating nanocomposite is engineered from CsPbBr3 nanoplatelets and Ag nanocubes to support exciton–plasmon strong coupling under X‐ray excitation. The resulting hybrid polaritonic states appear directly in radioluminescence, opening a route toward polariton‐enabled scintillator design beyond conventional Purcell enhancement.
Michal Makowski   +13 more
wiley   +1 more source

Epitaxially Integrated Electro‐Optic KNbO3 Thin Films on Silicon

open access: yesAdvanced Materials, EarlyView.
We demonstrate the first epitaxial integration of electro‐optic KNbO3 thin films on silicon using suboxide molecular‐beam epitaxy. Combining adsorption‐controlled molecular‐beam epitaxy, advanced characterization, and phase‐field modeling, we demonstrate phase‐pure crystalline films mirroring bulk crystals with robust Pockels response, enabling future ...
Sankalpa Hazra   +17 more
wiley   +1 more source

Selective Laser Sintering and Graphitization for Mono‐Matrix Unibody Fabrication of Integrated Stereo‐Circuit and Stereo‐Fluidic Wearable Electronics

open access: yesAdvanced Materials, EarlyView.
A novel selective laser sintering and graphitization (SLSG) 3D printing technology enables unibody fabrication of compacted insulating structures and conductive circuits in fluidic‐integrated wearable electronics through adaptive photonic modulation.
Li Zhang, Wing Cheung Mak
wiley   +1 more source

Systolic pressure variation and pulse pressure variation during modifications of arterial pressure

Intensive Care Medicine, 2008
This study was performed to investigate the effect of vasopressor therapy on systolic pressure variation (SPV) and pulse pressure variation (PPV) compared to experimentally measured left ventricular stroke volume variation (SVV).Prospective study in a university laboratory.Twelve anesthetized and mechanically ventilated pigs.Increase in mean arterial ...
Thorsten Annecke
exaly   +4 more sources

The impact of sedation on pulse pressure variation

Australian Critical Care, 2015
Pulse pressure variations (PPV) are mainly influenced by ventilation. The impact of sedation on PPV is not known. The aim of the study was to test the influence of sedation on pulse pressure variation in mechanically ventilated critically ill patients and to compare PPV in critically ill and brain dead patients.
Pavel Suk   +2 more
exaly   +3 more sources

A Novel Approach to Pulse Pressure Variation Estimation

2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006
We describe a novel algorithm to estimate the pulse pressure variation index (PPV) from arterial blood pressure signals (ABP). PPV has been shown to be one of the best predictors of fluid responsiveness in mechanically ventilated subjects. Our PPV algorithm uses a non-linear technique for envelope estimation, eliminating the need for automatic beat ...
Daniel Austin   +2 more
openaire   +3 more sources

Pulse pressure variation and systolic pressure variation in horses undergoing general anesthesia

Journal of Veterinary Emergency and Critical Care, 2012
AbstractIntroductionChanges in arterial pressure due to respiratory phases have been used to predict fluid responsiveness in a number of species and pulse pressure variation (PPV) and systolic pressure variation (SPV) are commonly used. The relationship between PPV and SPV has not been described in horses.ObjectivesTo describe and compare PPV and SPV ...
C Langdon, Fielding, Diana N, Stolba
openaire   +2 more sources

Home - About - Disclaimer - Privacy